TROUBLE-SHOOTING GUIDE
!Always unplug vacuum from outlet before dismantling any part of the machine!
PROBLEM | REASON | SOLUTION | ||
|
|
|
| |
Does not turn on | 1. Telescopic tubenot inserted properly. | 1. | See page 7. | |
|
|
|
|
|
| 2. | Not plugged into working outlet. | 2. | Use another outlet. |
|
|
|
|
|
| 3. | Cable worn. | 3. | Replace cable. |
|
|
|
|
|
| 4. | K3: The power control slider | 4. | K3: Set slider switch to “on” |
|
| switch is set to “0” (“off” position). |
| position. See page 9. |
|
|
|
| |
Bag full or clog light on | 1. Bag full. | 1. | Replace filter bag. See page 11. | |
Bag full or clog light on |
|
|
|
|
|
|
|
| |
& machine shuts off | 2. Clog in hose, telescopic tube, | 2. | See Clog Removal on page 12. | |
|
| brush or head, or entrance to |
| K3 users with clog in power head |
|
| filter bag. |
| attachment: refer to clog removal |
|
|
|
| in the |
|
|
|
| manual. |
|
|
|
|
|
| 3. | 3. | Replace | |
|
|
|
| See page 11. |
|
|
|
|
|
| 4. | Exhaust filter dirty. | 4. | Replace exhaust filter. See page 11. |
|
|
|
| |
Does not pick up | 1. Hose/handle assembly not | 1. | Reinsert hose/handle assembly | |
|
| correctly inserted. |
| making sure that it is lined up |
|
|
|
| properly and is snapped into |
|
|
|
| place. See page 7. |
|
|
|
|
|
| 2. | The suction control dial is rotated | 2. | K2: Rotate suction control |
|
| to no suction setting |
| dial to yellow setting. See page 8. |
|
|
|
|
|
| 3. | Filter bag cover not closed. | 3. | See below. |
|
|
|
| |
Filter bag door won’t | 1. Filter bag cover not fully closed. | 1. | Reinsert bag. Lock the cover | |
fully close |
|
|
| down firmly. |
|
|
|
|
|
| 2. | Bag not inserted properly | 2. | Reinsert bag. lock the cover |
|
|
|
| down firmly. |
|
|
|
|
|
| 3. | 3. | Remove the filter bag cover (26) and | |
|
| inserted. |
| make sure the |
|
|
|
| housing is seated firmly in place |
|
|
|
| (see pg. 11, figure 18). |
|
|
|
|
|
13