Wolf dimensions Model CTWH36 Cooktop Wall Hood, Planning Information, 24 TO

Models: CTWH36

1 9
Download 9 pages 5.2 Kb
Page 7
Image 7
D U C T I N G C O N S I D E R A T I O N S

Planning Information

Model CTWH36 Cooktop Wall Hood

D U C T I N G C O N S I D E R A T I O N S

Wolf cooktop wall hoods are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available. For wall hoods, the remote blower can be mounted on the roof or an exterior wall.

IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.

Wolf cooktop wall hoods have an 8" (203) round vertical discharge. Ducting for wall hoods can run through the roof or an external wall as shown in the illustration below.

Refer to the Cooktop ventilation charts at the end of this section for recommendations and blower options.

 

DUCTWORK INSTALLATION

 

THROUGH ROOF

ROOF CAP OR REMOTE BLOWER –

 

TRANSITION FROM 8" (203) TO 10" (254) DUCT

 

REQUIRED FOR REMOTE BLOWER

 

8" (203) ROUND DUCT

 

 

WALL CAP

CHIMNEY FLUE EXTENSION

OR REMOTE BLOWER

TELESCOPIC CHIMNEY FLUE

 

 

DUCTWORK INSTALLATION

8" (203) ROUND ELBOW

THROUGH WALL

8" (203) ROUND DUCT

 

 

8" (203) ROUND

 

VERTICAL DISCHARGE

67/8" (175) OR 91/4" (235)

COOKTOP

WALL HOOD

 

21"

24" TO 30"

(535)

(610–762)

 

COUNTERTOP

 

TO BOTTOM OF

 

VENTILATION HOOD

 

Ducting considerations cooktop wall hoods.

Dimensions in parentheses are in

millimeters unless otherwise specified.

7

Page 7
Image 7