Planning Information

Integrated Gas Cooktop

M O D E L C T 1 5 G / S

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions, cut-out dimensions and installation specifics.

When multiple integrated cooktop modules are installed side by side, refer to the counter- top cut-out dimensions on page 6.

A Wolf downdraft system, Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to the ventilation recommendation charts in the cooktop or Pro ventilation sections of our website, wolfappliance.com.

The Wolf integrated gas cooktop requires a separate 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the

6' (1.8 m) power cord. Locate electrical within the shaded area shown in the illustration on page 4.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

For the integrated gas cooktop, the gas service may be supplied through the floor if the cooktop is not installed above an oven. Refer to the illustration on page 4 for placement of electrical and gas supply.

Wolf gas cooktops are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14"

(34.9 mb) WC; .5 psi (3.5 kPa). It is supplied with a 1/2" NPT male gas connection at the right rear bottom corner of the cooktop. The male connector exits the unit straight down and you are supplied with a regulator with two female connectors.

You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.

Wolf gas cooktops using natural gas function up to an altitude of 8,000' (2438 m) without any adjustment. Natural gas installa- tions from 8,000' (2438 m) to 10,000' (3048 m) need the high altitude conversion kit. LP gas installations will operate up to 10,000' (3048 m) without adjustment.

Refer to the installation instructions shipped with each Wolf product for detailed specifications.

This cooktop is intended for indoor use only.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Page 5
Image 5
Wolf Appliance Company CT15G/S dimensions Installation N O T E S