Wolf Appliance Company Drawer Microwave Anti -Ti P B Loc K, I Ns Tal L An Ti- Tip B Loc Ki Ng

Models: Drawer Microwave

1 12
Download 12 pages 35.92 Kb
Page 9
Image 9
ANTI -TI P B LOC K

INSTAL LATI ON INSTR U C TIO N S

ANTI -TI P B LOC K

I NS TAL L AN TI- TIP B LOC KI NG

To reduce the risk of tipping of the drawer, the Anti-Tip block must be properly installed located 1413/16" (376) above the floor on which the drawer microwave will sit. The 6" (152) Anti-Tip block must be provided by the installer. See pages 6–7. The Anti-Tip block prevents serious injury that might result from spilled hot liquids.

If the drawer microwave is ever moved to a different location, the Anti-Tip block must also be moved and installed. When installed to the wall, make sure that the screws completely penetrate the dry wall and are secured in wood or metal so that the block is totally stable. When fastening, be sure that the screws do not penetrate electrical wiring or plumbing.

EL ECTR IC AL RE QU IR E M EN TS

ELEC TR IC AL OU TL ET LO C ATI O N

The electrical requirements are a 120 volt 60 Hz, AC only, 15 amp or more protected electri- cal supply. It is recommended that a separate circuit serving only this appliance be provided.

The drawer is equipped with a 3-prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded. Should you only have a 2-prong outlet, have a qualified electrician install a correct wall receptacle.

NOTE: If you have any questions about the grounding or electrical instructions, consult a qualified electrician or service person.

I M PO RTA N T NO T E

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

6" (153)

Anti-tip

Block

Anti-tip block

Electrical Outlet

Location

5" (127)

4"

(102)

Electrical Outlet

Dimensions in parentheses are in

 

millimeters unless otherwise specified.