Installation 11
MAN0406 (Rev. 9/7/2007)
HYDRAULIC INSTALLATION
Keep hands and body away from pressurized
lines. Use paper or cardboard, not hands or other
body parts to check for leaks. Wear safety gog-
gles. Hydraulic fluid under pressure can easily
penetrate skin and will cause serious injury or
death.
Make sure that all operating and service per-
sonnel know that if hydraulic fluid penetrates
skin, it must be surgically removed as soon as
possible by a doctor familiar with this form of
injury or gangrene, serious injury, or death will
result. CONTACT A PHYSICIAN IMMEDIATELY IF
FLUID ENTERS SKIN OR EYES. DO NOT DELAY.
Make sure all hydraulic hoses, fittings, and
valves are in good condition and not leaking
before starting power unit or using equipment.
Check and route hoses carefully to prevent dam-
age. Hoses must not be twisted, bent sharply,
kinked, frayed, pinched, or come into contact with
any moving parts. Operate moveable components
through full operational range to check clear-
ances. Replace any damaged hoses immediately.

Assemble Bulkhead Bracket

1. Connect bulkhead ad apter (3) to bulkhead
bracket (6) and secure using hex nut provided
with adapter.
2. Attach female qu ick coupler (16) to the backside
of bulkhead adapter (3) and elbow (13) to the
front side. Position elbow to point upward.
3. Remove front hex n ut and washer that connect
offset bar to the right tractor bracket.
4. Place bulkhead bracket on the inside of the trac-
tor bracket and secure into position using hex nut
and washer previously removed.
3. 1009495 Adapter, 3/8 NPTM x 9/16 JICF
6. 1013521 Bulkhead bracket
13. 38604 Elbow, 9/16 JICM x 9/16 JICF 90°
16. 64299 Quick coupler, female 3/8
Figure 17. Bulkhead Bracket Installed Figure 18. Bulkhead Bracket Installation
DP10