HYDRAULIC INSTALLATION
Keep hands and body away from pressurized lines. Use paper or cardboard, not hands or other body parts to check for leaks. Wear safety gog- gles. Hydraulic fluid under pressure can easily penetrate skin and will cause serious injury or death.
Make sure that all operating and service per- sonnel know that if hydraulic fluid penetrates skin, it must be surgically removed as soon as possible by a doctor familiar with this form of injury or gangrene, serious injury, or death will result. CONTACT A PHYSICIAN IMMEDIATELY IF FLUID ENTERS SKIN OR EYES. DO NOT DELAY.
Make sure all hydraulic hoses, fittings, and valves are in good condition and not leaking before starting power unit or using equipment. Check and route hoses carefully to prevent dam- age. Hoses must not be twisted, bent sharply, kinked, frayed, pinched, or come into contact with any moving parts. Operate moveable components through full operational range to check clear- ances. Replace any damaged hoses immediately.
Assemble Bulkhead Bracket
1. | Connect bulkhead adapter (3) to bulkhead | 3. | 1009495 | Adapter, 3/8 NPTM x 9/16 JICF |
| bracket (6) and secure using hex nut provided | 6. | 1013521 | Bulkhead bracket |
| with adapter. | 13. | 38604 | Elbow, 9/16 JICM x 9/16 JICF 90° |
|
| |||
2. | Attach female quick coupler (16) to the backside | 16. | 64299 | Quick coupler, female 3/8 |
| of bulkhead adapter (3) and elbow (13) to the |
|
|
|
| front side. Position elbow to point upward. |
|
|
|
3.Remove front hex nut and washer that connect offset bar to the right tractor bracket.
4.Place bulkhead bracket on the inside of the trac- tor bracket and secure into position using hex nut and washer previously removed.
DP10
Figure 17. Bulkhead Bracket Installed | Figure 18. Bulkhead Bracket Installation |
MAN0406 (Rev. 9/7/2007) | Installation 11 |
|
|