110V Operation
The SHOP FOX® Model W1717 1⁄3 HP, 110 volt motor draws approximately 4 amps.
Since other machines may be using the same circuit, make sure the circuit, circuit breaker, or fuse can carry the total load without tripping. If the total amperage load of all machines and the sander exceeds the amperage rating of the circuit breaker or fuse, use a different circuit that can carry the load.
DO NOT modify an existing
Extension Cords
If you must use an extension cord with the Model W1717, please follow these requirements:
•Use a cord rated for Standard Service (Grade S).
•Use a cord that is 100 feet or less.
•Use a least a 16 gauge cord.
•Use a cord with a ground pin.
•Use an undamaged cord only.
Grounding
Serious injury or fire may
occur if you plug this
machine into a receptacle that is not grounded. Connect this machine to grounded outlets only!
Ground this machine! The electrical cord sup- plied with the SHOP FOX® Model W1717 sander has a three prong plug for grounded outlets. See Figure 2. If your power receptacle does not have a ground pin hole, have the receptacle replaced by a qualified electrician, or have an appropriate adapter installed and grounded properly. NEVER cut the ground pin off so your sander plug fits into a
NOTICE
When using an electrical plug adapter, make sure the adapter is grounded.
Remember, an adapter with a grounding wire does not guarantee the sander is grounded. A ground source must always be verified in the electrical circuit within the wall or conduit.