REMOTE ROOM
3-Terminal Block (supplied)
283M Blink-IR™
Mouse Emitter
RCVR
3-ConductorInter-room Cable (unshielded OK)
7' Ribbon Cable
GND
IR IN
+12V
STATUS
GND
IR OUT
A/V Receiver
+12 VDC
Red (or white) Stripe
283M Emitter
12VDC
2-1/8"
VCR
Connecting Block
Hand Held
Remote
Red
Talkback LED
789-44
283M Emitter
To 120 V AC (unswitched)
While it is possible to make wired connec- tions without the connecting block, it is not recommended. The connecting block re-
duces installation time, helps to eliminate errors, allows easy troubleshooting and per- mits easy system upgrades later, if needed. Input connections must be made as illus-
trated. To extend the Emitter wires to a more
distant location, you may splice in 2-conductor wire, in the wire gauges mentioned
IR Photodiode
Power Supply
7/16" IR Receivers
Satellite Receiver
480-00Series
781RG
INSTALLATION
Model 480-00 Series. These units are intended to be wired to the input terminals of Xantech Connecting Blocks or other devices, using the supplied 3-terminal block in the remote room location. A 3-conductor cable (24 gauge up to 200', 22 gauge up to 600', 20 gauge up to 2000', 18 gauge up to 5000'), is run to the main room. Connections are then made to a Xantech connecting block, power supply and emitters as shown in the following illustration of a typical
basic system:

IR

®

789-44 CONNECTING BLOCK

EMITTERS

MAIN ROOM

before, as needed.

Model 480-30 Series. These units, equipped with a 7-foot cable and 3.5 mm stereo type mini plug, are plugged directly into the "IR RCVR" or "AUX" jack on Xantech Connecting Blocks, such as the CB12, CB20, 789-44, 791-44, etc. The 480-30 should be used in installations where the connecting block is within reach of the 7-foot cable -- such as when installing the 480-30 on a cabinet where the controlled equipment is

behind closed doors.

480-30 Series

IR Receivers

791-44

 

Amplified

Satellite Receiver

Connecting Block

 

A typical system, with a 480-30, 781RG Power Supply and 282M Emitters plugged into a 791-44

Red

Talkback LED

IR Photodiode

Hand Held

Remote

480-30 (mounted on or near cabinet in an inconspicuous location).

Controlled Equipment (mounted behind closed cabinet doors)

IR OUT

HIGH

IR RCVR

 

7 Foot Ribbon

+ 1 2 V D C

Cable with Quick

G N D

Connect Mini Plug

S TAT U S

 

I R I N

To 120 V AC

®

CONNECTING

791-44 AMPLIFIED

781RG

 

 

 

Power Supply

 

 

 

(unswitched)

 

BLOCK

 

12 VDC

 

 

E M I T T E R S

283M Emitter

VCR

283M Emitter

AV Receiver

283M Emitter

CD Changer

283M Emitter

Cassette DecK

283M Blink-IR™

Mouse Emitter

Amplified Connecting Block, is shown in the diagram to the left.

Mounting: The 480-00 and 480-30 series can be mounted to any flat surface, using the 3/8" x 1-3/ 4" two-sided adhesive tape supplied. Two screws are included for mounting the 3-terminal block provided with the 480-00 series. Affix the Mini- Emitters, such as the 282, 283, 284 and 286 series, to the IR sensor windows of the controlled equipment in accord with the instructions that come with them.

480-30 Cable Connections

480-30's may also be used where the 7-foot lead is not long enough. In this case, you would simply cut off the mini plug, strip the leads and connect them to a 3-terminal block in the same way as you would for the

480-00. To do this, you will need the lead identification as given in the following table and diagram:

 

 

 

480-30Series IR Receivers

Plug

Ribbon Cable

Circuit Item

 

 

 

 

 

 

3-Conductor Wire to

Ring

Outer Lead

Ground

WHITE Stripe

Controlled Equipment

 

Tip

White Stripe

Signal

OUT

 

+12V

 

 

 

 

GND

 

Sleeve

Center Lead

+ 12 V

 

 

 

 

 

7-Foot Ribbon Cable with

3-Terminal Block

 

 

 

Mini Plug removed

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

480 Series

Page 2
Image 2
Xantech 480W-30, 480B-00, 480B-30, 480W-00 installation instructions Before, as needed, Behind closed doors