REMOTE ROOM
3-Terminal Block (supplied)
283M Blink-IR™
Mouse Emitter
RCVR
3-ConductorInter-room Cable (unshielded OK)
7' Ribbon Cable
GND
IR IN
+12V
STATUS
GND
IR OUT
A/V Receiver
+12 VDC
Red (or white) Stripe
283M Emitter
12VDC
2-1/8"
VCR
Connecting Block
Hand Held
Remote
Red
Talkback LED
789-44
283M Emitter
To 120 V AC (unswitched)
While it is possible to make wired connec- tions without the connecting block, it is not recommended. The connecting block re-
duces installation time, helps to eliminate errors, allows easy troubleshooting and per- mits easy system upgrades later, if needed. Input connections must be made as illus-
trated. To extend the Emitter wires to a more
distant location, you may splice in 2-conductor wire, in the wire gauges mentioned
IR Photodiode
Power Supply
7/16" IR Receivers
Satellite Receiver
480-00Series
781RG
INSTALLATION
Model 480-00 Series. These units are intended to be wired to the input terminals of Xantech Connecting Blocks or other devices, using the supplied 3-terminal block in the remote room location. A 3-conductor cable (24 gauge up to 200', 22 gauge up to 600', 20 gauge up to 2000', 18 gauge up to 5000'), is run to the main room. Connections are then made to a Xantech connecting block, power supply and emitters as shown in the following illustration of a typical
basic system:
® | 789-44 CONNECTING BLOCK | EMITTERS |
MAIN ROOM
before, as needed.
Model 480-30 Series. These units, equipped with a 7-foot cable and 3.5 mm stereo type mini plug, are plugged directly into the "IR RCVR" or "AUX" jack on Xantech Connecting Blocks, such as the CB12, CB20, 789-44, 791-44, etc. The 480-30 should be used in installations where the connecting block is within reach of the 7-foot cable -- such as when installing the 480-30 on a cabinet where the controlled equipment is
behind closed doors.
480-30 Series
IR Receivers
| 791-44 | |
| Amplified | Satellite Receiver |
| Connecting Block |
| |
A typical system, with a 480-30, 781RG Power Supply and 282M Emitters plugged into a 791-44
Red
Talkback LED
IR Photodiode
Hand Held
Remote
480-30 (mounted on or near cabinet in an inconspicuous location).
Controlled Equipment (mounted behind closed cabinet doors)
IR OUT | HIGH |
IR RCVR | |
7 Foot Ribbon | + 1 2 V D C |
Cable with Quick | G N D |
Connect Mini Plug | S TAT U S |
| I R I N |
To 120 V AC | ® | CONNECTING | 791-44 AMPLIFIED |
781RG | | | |
Power Supply | | | |
(unswitched) | | BLOCK | |
12 VDC | | |
E M I T T E R S
283M Emitter
VCR
283M Emitter
AV Receiver
283M Emitter
CD Changer
283M Emitter
Cassette DecK
283M Blink-IR™
Mouse Emitter
Amplified Connecting Block, is shown in the diagram to the left.
Mounting: The 480-00 and 480-30 series can be mounted to any flat surface, using the 3/8" x 1-3/ 4" two-sided adhesive tape supplied. Two screws are included for mounting the 3-terminal block provided with the 480-00 series. Affix the Mini- Emitters, such as the 282, 283, 284 and 286 series, to the IR sensor windows of the controlled equipment in accord with the instructions that come with them.
480-30 Cable Connections
480-30's may also be used where the 7-foot lead is not long enough. In this case, you would simply cut off the mini plug, strip the leads and connect them to a 3-terminal block in the same way as you would for the
480-00. To do this, you will need the lead identification as given in the following table and diagram:
| | | 480-30Series IR Receivers |
Plug | Ribbon Cable | Circuit Item | | |
| | | | 3-Conductor Wire to |
Ring | Outer Lead | Ground | WHITE Stripe | Controlled Equipment |
|
Tip | White Stripe | Signal | OUT | |
+12V | |
| | | GND | |
Sleeve | Center Lead | + 12 V | | |
| | | 7-Foot Ribbon Cable with | 3-Terminal Block |
| | | Mini Plug removed | |