Xantech MRC44CB1 installation instructions Troubleshooting, Xantech Corporation

Models: MRC44CB1

1 4
Download 4 pages 60.44 Kb
Page 4
Image 4

Page 4

D

400 feet max (122 m)

Model MRC44CB1

781RG Power Supply

IR Receiver

MRC44CB1

PWR

CONTROLLER

KEYPAD

 

SIG

IR IN

 

+12V GND

600 feet max (183 m)

Figure 2d – Example D

EXAMPLE D

EXTENDING THE OVERALL LENGTH BETWEEN MRC44 KEYPADS

This is applicable when the overall distance between the MRC44 Controller and the last MRC44 Keypad in the chain is greater than 200ft.

1.Remove the jumper across JP1 on the MRC44CB1 connecting block

2.From the Primary MRC44 Keypad, run a CAT5 to the location where the MRC44CB1 connecting block will be

located.

Note: The Primary Keypad must be within 400ft of the MRC44 Controller

3.Mount MRC44CB1 to a convenient location using the Adhesive strip supplied

4.Properly terminate both ends of the cable with RJ45 connectors. Plug one end into the connector labeled Expansion on the MRC44 Keypad and the other end into the connector labeled Controller on the MRC44CB1 connecting block.

5.Run another CAT5 cable from the MRC44CB1 connecting block to the location of the next keypad (up to 250 ft.) and properly terminate both ends with RJ45 Connectors

6.Plug one end into the connector labeled Keypad on the MRC44CB1 and the other end into the connector labeled Controller on the MRC44 Keypad

7.Plug a 782-00 Power Supply into the 2.5mm Coaxial jack on the MRC44CB1 connecting block labeled PWR

CAUTION! Do not plug in a 781RG or any other Power Supply into the MRC44CB1 when a jumper is placed across JP1.

TROUBLESHOOTING

1.Power Supply getting warm:

a.When using external power supply, make sure jumper is removed from JP1 on the MRC44CB1 Connecting Block

b.Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations

2.IR Receive Confirmation LED lights on MRC44CB1 when IR signal transmitted, but emitters do not flash at MRC44 and no control of external sources. All control works fine when controlling from MRC44 Keypads.

a.CAT5 RJ45 connection at last keypad is plugged into EXPANSION connector instead of KEYPAD

b.Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations

3.Still getting IR Interference even when using “CFL Friendly” or “Plasma Friendly” IR Receiver:

a.IR Receiver on MRC44 Keypads needs to be disabled. Remove jumper across Sensor Enable pins on rear of MRC44 Keypad (refer to MRC44 Instruction Manual)

b.Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations or interference from adjacent cable runs, Dimmer Controls etc.

XANTECH CORPORATION

12950 Bradley Avenue, Sylmar CA 91342-3829

phone 818.362.0353 • fax 818.362.9506

Part No. 08901185 Rev B 09-04-2003

Page 4
Image 4
Xantech MRC44CB1 installation instructions Troubleshooting, Xantech Corporation