Xantech MRKP2 - FRONT PANEL, RJ45 Connector at, Controller/Amplifier, Cable, at Keypad

Models: MRKP2

1 12
Download 12 pages 36 Kb
Page 5
Image 5
MRKP2 – FRONT PANEL

MRKP2 – FRONT PANEL

Figure 2.1: T568A and T568B Wiring Standard

RJ45 Connector at

Controller/Amplifier

Wire Color

Pin #

Signal

white/orange

1

485

+

 

 

 

 

orange

2

485

-

 

 

 

 

white/green

3

12V RET

 

 

 

 

blue

4

IR RET

 

 

 

 

 

 

 

 

white/blue

5

IR

 

 

 

 

 

 

NAVIGATION BUTTONS

UP, DOWN, LEFT, RIGHT,

ENTER/SELECT (center button)

 

MAIN

 

DISPLAY

SCAN

 

FWD/RRW

scan

 

volum e

 

skip

TRACK SKIP

 

NEXT/PREV

 

PAUSE

STOP

POWER

ON/OFF

INTERNAL IR SENSOR

“ X” (SETUP)

VOLUME

UP/DN

MUTE

PLAY

 

 

green

6

+12V

 

 

white/brown

7

Attn. 485

 

 

brown

8

IR Loop Back

 

 

Cat 5

RJ45 Connector

 

 

 

Cable

Wire Color

Pin #

Signal

 

at Keypad

 

white/orange

1

485 +

 

 

orange

2

485 -

 

 

white/green

3

12V RET

 

 

blue

4

IR RET

 

 

white/blue

5

IR

 

 

green

6

+12V

 

 

white/brown

7

Attn. 485

 

 

 

 

brown

8

IR Loop Back

Figure 2.2: MX88 – MRKP2 Pin-out diagram for Cat-5 cable

(T568B configuration)

8

Figure 2.3: MRKP2 Keypad layout and Main display

Notes:

Tone Control functions of the MRKP2 can be entered by pressing the Next arrow once inside a source control page. Please note that each of the three controls can be returned to their center position by tapping the center of each bar.

Unlike older keypads, and due to the unique and streamlined functional set-up of the MRKP2E’s buttons, “press-and-hold” tier 2 functions are not supported. However, Tier 2 button IDs and the macros underneath them are available through Universal Dragon.

9

Page 5
Image 5
Xantech installation instructions MRKP2 - FRONT PANEL, RJ45 Connector at, Controller/Amplifier, Cable, at Keypad