TROUBLESHOOTING CHART

TROUBLESHOOTING CHART

PROBLEM

CAUSE

SOLUTION

No Power, Nothing Runs

1.

Is the cord plugged in.

2.

Circuit breaker tripped in building.

 

 

3.

Faulty switch.

 

4.

Faulty power cord or pigtail.

Vacuum Motor Will Not

1. Vacuum circuit breaker tripped.

Run

2. Faulty main vacuum switch.

 

3.

Loose wiring.

 

4.

Faulty vac motor.

Vacuum Motor Runs But

1. Debris lodged in vac shoe.

Suction Is Poor

2. Dome gasket defective or missing.

 

3.

Vacuum hose cracked or hose cuff loose.

 

4.

Recovery tank full / float ball stuck in the up

 

 

position.

Poor Or No Water Flow

1. Main pump switch off.

(Carpet Is Streaky)

2. Jets clogged or missing.

 

3.

Solution filter clogged.

 

4.

Faulty solenoid.

Brush Does Not Spin

1.

Brush switch off.

2.

Brush circuit breaker tripped

 

 

3.

Brush belt broken.

 

4.

Faulty brush motor.

1.Plug in cord.

2.Reset breaker

3.Call for service.

4.Call for service.

1.Reset breaker

2.Call for service.

3.Call for service.

4.Call for service.

1.Remove debris from vac shoe.

2.Replace as necessary.

3.Replace or repair as necessary.

4.Turn off vac motor. Drain and rinse recovery tank.

1.Turn on.

2.Clean using a vinegar /water solution or replace.

3.Drain solution tank and clean solution filter.

4.Call for service.

1.Turn on brush switch.

2.Reset circuit breaker.

3.Replace as necessary.

4.Call for service.