Installation
9.Install the lock washer and nut that are supplied with the inverter. Tighten the nut to a torque of
CAUTION
Loose connections cause excessive voltage drop and may cause overheated wires and melted insulation.
CAUTION
Do not over tighten the nut on the DC input terminals. Damage to the DC input terminals may result.
The maximum torque setting is
DC power connections to the XPower Plus must be positive to positive and negative to negative.
A reverse polarity connection (positive to negative) will blow a fuse in the inverter and may permanently damage the inverter. The fuse is not user replaceable and the inverter may need to be returned for servicing.
Damage caused by a reverse polarity connection is not covered by your warranty.
10.Before proceeding, double check that the cable you have just installed connects the positive DC terminal of the inverter to the fuse holder, and that the other end of the fuse holder is connected to the positive terminal on the battery.