Warning! Risk of damage to the 300 Inverter.

Reversing the positive and negative battery cables will damage the inverter and will void your warranty.

Before connecting the inverter to the battery, double check the connections: the red wire must be connected to the red terminal on the inverter and the positive (+) terminal on the battery; the black wire must be connected to the black terminal on the inverter and the negative (–) terminal on the battery.

6.Remove the nuts from the DC terminals of the inverter.

7.Place the red ring connector on the red (positive +) DC terminal on the inverter, and then screw the red nut on until it is snug. Do not over tighten.

8.Fasten the positive terminal (red wire) to the positive battery post.

9.Fasten the negative terminal (black wire) to the negative battery post.

10.Place the black ring connector on the black (negative –) DC terminal on the inverter, and then screw the black nut on until it is snug. Do not over tighten.

11.Turn on the in-line switch.

12.Turn on the inverter’s On/Standby switch. The PWR light comes on, and AC power is available at the outlet.

16