This section describes problems, their symptoms, possible causes, and specific remedies.

PROBLEM: AC product will not operate, no inverter warning lights are ON.

Possible cause

Remedy

 

 

Battery is defective.

Check battery and replace if required.

Inverter has been connected with

Check connection to battery. Probable

reverse DC input polarity.

inverter damage has occurred. Have

 

unit repaired (not covered by

 

warranty).

Loose cable connections.

Check cables and connections. Tighten

 

as required.

PROBLEM: Inverter will run some small loads, but not larger ones.

Possible cause

Remedy

 

 

Voltage drop across DC cables.

Shorten cables or use heavier cables.