Xantrex Technology 450 owner manual To hardwire the inverter to a 12 V battery

Models: 450

1 40
Download 40 pages 17.82 Kb
Page 18
Image 18

5 4

+

3

2

1

Figure 1 Hardwiring the inverter to a 12 V battery

1.XPower Inverter 450

2.8 AWG red wire from the positive inverter terminal to the positive battery terminal (via the fuse)

3.60 A automotive or marine fuse

4.12 V battery

5.8 AWG black wire from the negative inverter terminal to the negative battery terminal

To hardwire the inverter to a 12 V battery:

1.Make sure the power inverter’s ON/OFF switch is in the OFF position.

2.Use an 8 AWG (or heavier) wire to a maximum total length of 2 m (6.5').

3.Install a 60 A automotive fuse in the positive (red) wire, close to the end that will attach to the battery.

14

Page 18
Image 18
Xantrex Technology 450 owner manual To hardwire the inverter to a 12 V battery