Troubleshooting

Table 1 Troubleshooting Reference

 

 

 

 

 

 

 

Problem

Possible Cause

Solution

 

 

 

 

 

Low output voltage (96 VAC–104 VAC)

You are using a voltmeter that cannot

Use a true RMS reading voltmeter such as the

 

 

accurately read the RMS voltage of a

Fluke 87.

 

 

modified sine wave.

 

 

 

Low input voltage and the load is close to

Check the connections and cable to see if the

 

 

maximum allowable power.

battery is fully charged. Recharge the battery

 

 

 

if it is low.

 

 

 

Reduce the load.

 

 

 

 

 

No output voltage. Both the Power Light and

The inverter is off.

Turn the inverter on.

 

Fault Light are off.

 

 

 

 

No power to the inverter.

Check the wiring to the inverter and to the

 

 

 

battery selector switch (if installed).

 

 

The inverter could have been connected with

The inverter has probably been damaged.

 

 

reverse DC input polarity.

Return the unit. Damage caused by reverse

 

 

 

polarity is not covered by the warranty.

 

 

 

Information for returning the inverter is

 

 

 

provided in “Return Procedure” on page 23.

 

 

 

 

 

No output voltage. Power Light is on.

GFCI was tripped.

Reset GFCI.

 

 

 

 

 