Table 1 Troubleshooting Reference

Problem

Possible Cause

Solution

 

 

 

No output voltage. Fault Light is on.

Low input voltage

Recharge the battery; check the connections

 

 

and cable.

 

High input voltage

Make sure the inverter is connected to a 12 V

 

 

battery.

 

 

Check the voltage regulation of the charging

 

 

system.

 

Thermal shutdown

Allow the unit to cool off. Reduce the load if

 

 

continuous operation is required.

 

 

Improve ventilation. Make sure the inverter’s

 

 

ventilation openings are not obstructed.

 

 

Reduce the ambient temperature.

 

Unit overload

Reduce the load. Make sure the load does not

 

 

exceed the inverter’s output rating.

 

Output is short circuited.

Remove the short circuit.

 

 

 

Low battery alarm stays on.

Poor DC wiring; poor battery condition

Use proper cable size and lengths and make

 

 

solid connections.

 

 

Charge the battery.

 

 

Install a new battery.

 

 

 