3–4 975-0390-01-01
To change the charger’s charging current setting:
By default the
charging current
is set to 55 A.
1. Press and hold the Power button for five seconds.
The LED screen will flash “Cur” intermittently.
2. Press the Select button once.
The LED screen will display the present charging current setting.
Example, “40A” for a 40 A setting.
3. Press the Select button again to change to the next setting.
The LED screen shows the next setting. Example, “2A” for a 2 A
setting.
4. Continue pressing the Select button to cycle through each of the four
settings – “2A”, “10A”, “20A”, and “40A” until you reach the desired
setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
Table 3-1
Charging Current Guidelines
AC Input Circuit Breaker
or fuse size
(Amps)
Charger DC Current
Setting
(Amps)
Maximum By-pass AC
Current Available
(Amps)
15 5 12.5
15 9.5
35 4.0
55 0
20 5 17.5
15 14.5
35 9.0
55 5.0
30 5 27.5
15 24.5
35 19.0
55 15.0