5–6 975-0390-01-01
E07 Over-temperature
warning Inverting • Reduce the loads connected to the AC
outlet of the unit.
• Check that the ventilation grille is not
blocked.
• Check for ambient temperature and move
the unit to a cooler location whenever
possible.
E08 not used
E09 not used
E10 High battery voltage
(> 15.5 V) AC shore
power • Check for external charging sources, such
as an over voltage alternator, and
disconnect if necessary.
• Confirm that the external charging source is
not the cause. The error may be caused by
the internal battery charger system. Call
Xantrex for support.
E11 Over-temperature
detected on the AC
transfer relay
AC shore
power • Reduce the loads connected to the AC
outlet of the unit.
• Check that the ventilation grille is not
blocked.
• Check for ambient temperature and move
the unit to a cooler location whenever
possible.
E12 Battery is bad or
external DC load is
connected to the
battery.
AC shore
power • Check the battery bank.
NOTE: The battery voltage did not rise
above 5 Vdc after 1 minute or 10 Vdc after
15 minutes.
• Check that the external DC load current
consumption is below the charging current
setting.
• Disconnect the DC load or increase the
charger current setting.
Table 5-1
Error Codes Displayed on the Display Panel Screen
Error Code Condition Mode Action