Operating in Inverter Mode
975-0390-01-01 4–5
Status LED During Inverter Mode

The following summarizes the behavior of the Status LED during Inverter

mode.

Checking Battery Status

During inverter mode, you can check the battery status by pressing the

Select button until the Input Voltage LED (or Input Current LED)

illuminates. The battery voltage (or battery current) appears in the three-

digit LED display screen when the Input Voltage LED (or Input Current

LED) illuminates.

The normal operating battery voltage range is between 11 and 15 volts.

Table 4-1

Status LED during Inverter Mode

Status LED Display Screen Condition
Solid
YELLOW

12.8

(where 12.8 is an
example of battery
voltage)
Select button is pressed to display Input Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.

11

(where 11 is an
example of current)
Select button is pressed to display Input Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.

0.85

(where 0.85 is an
example of output
power in Kilowatts)
Select button is pressed to display Output Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.

E05 through e07 Warning condition detected while AC output power is still

available.
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.
Solid RED E01 through e04 Fault condition detected and AC output power is not
available. The unit will sound an alarm and will shutdown
completely within 30 seconds.
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.
Off Off Inverter is OFF.
Off (or Yellow) 00.0No communication between the Freedom HF and the Display
Panel because the battery voltage was too low to start the
Inverter.