Adjusting Feature Settings
975-0390-01-01 3–5
To change the inverter mode setting:
By default the
inverter mode is
set to ON.
ON (“In1”) will put the inverter on standby. This means when
shorepower is present, AC shorepower will pass through as AC output.
And when shorepower is not available, the inverter function will take
power from the battery and provide AC output power. When the inverter
mode is ON, you can manually turn the inverter function ON or OFF by
using the Power button. See “Operating in Inverter Mode” on page 4–4.
OFF (“In0”) will completely disable inverter function. This means when
shorepower is present, AC shorepower will still pass through as AC
output. However, when shorepower is not available, the inverter function
remains disabled and therefore no AC output power. When the inverter
mode is OFF, you cannot manually turn the inverter function ON or OFF
by using the Power button.
1. Press and hold the Power button for five seconds.
2. Press the Power button once.
The LED screen will flash “In” intermittently.
3. Press the Select button once.
The LED screen will display the present (or most recent) inverter
mode setting.
Example, “In1” for an inverter mode setting of ON or “In0” for an
inverter mode setting of OFF.
4. Continue pressing the Select button to cycle through the two settings
– “In1” and “In0” until you reach the desired setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
To adjust the alarm setting:
By default the
alarm is set to
ON.
ON (“AL1”) will sound the alarm on all warning and fault conditions.
OFF (“AL0”) will mute the alarm.
1. Press and hold the Power button for five seconds.
2. Press the Power button twice.
The LED screen will flash “AL” intermittently.
3. Press the Select button once.
The LED screen will display the present (or most recent) alarm
setting.
Example, “AL1” for an inverter mode setting of ON.