Appendix C: Troubleshooting

 

 

 

 

 

 

 

Error

Description of Fault

Possible Cause

Solution

 

Code

 

 

 

 

 

 

 

 

 

 

008-015

Ambient temperatures or

1. Power required by AC load

1. Reduce AC load to spec-

 

 

internal component temper-

is too high.

ified limits. Reduce AC load

 

 

atures are too high or too

 

below rated maximum if

 

 

low.

 

room temperature is above

 

 

 

 

25ºC / 77ºF. See tempera-

 

 

 

 

ture de-rating curve in

 

 

 

 

Owner’s Manual.

 

 

 

2. Blocked ventilation.

2. Allow more room for air

 

 

 

 

circulation around unit.

 

 

 

3. Room temperature too high

3. Allow more ventilation in

 

 

 

 

compartment.

 

 

 

4. Room temperature too low.

4. In extremely cold cli-

 

 

 

 

mates (below freezing), a

 

 

 

 

heated room may be

 

 

 

 

required

 

 

 

 

 

 

064

AC Output Overcurrent

Temporary AC output over-

Reduce AC load so that

 

 

 

load. The higher the output

even for short times, the

 

 

 

current, the faster the unit will

AC output current does not

 

 

 

shut down (minimum 2 sec-

exceed 26 A. See Overcur-

 

 

 

onds).

rent Protection curve in this

 

 

 

 

manual.

 

 

 

 

 

 

066

Communication Fault

1. Faulty cable between Pros-

1. Check display cable con-

 

 

 

ine and remote panel.

nections and attempt

 

 

 

 

restart. If problem persists,

 

 

 

 

try a replacement cable. If

 

 

 

 

problem still persists, call

 

 

 

 

Xantrex.

 

 

 

2. Internal Fault

2. Record the error code

 

 

 

 

and contact Xantrex.

 

 

 

 

 

 

129-134

Internal fault

Various. There could be a

Record the error code and

 

 

 

fault inside the unit or the

contact Xantrex.

 

 

 

microprocessor is fooled by

 

 

 

 

 

some external condition.

 

 

 

 

 

 

 

 

135

Battery voltage stays low in

24 VDC model connected to a

Correct the battery wiring or

 

 

charge mode

12 V battery or a 12 VDC

replace Prosine with differ-

 

 

 

model is connected to a 6 V

ent battery nominal Dc volt-

 

 

 

battery

age.

 

 

 

 

 

 

136,192-

Internal fault

Various. There could be a

Record the error code and

 

194

 

fault inside the unit or the

contact Xantrex.

 

 

 

microprocessor is fooled by

 

 

 

 

 

some external condition.

 

 

 

 

 

 

 

 

Prosine 2.5/3.0 Installation & Operation Guide

91

Page 109
Image 109
Xantrex Technology PS2.5, PS3.0 installation and operation guide Appendix C Troubleshooting

PS3.0, PS2.5 specifications

Xantrex Technology has made significant strides in the power electronics sector with the introduction of their PS2.5 and PS3.0 inverter models. These inverters are designed primarily for solar energy applications, offering reliable and efficient power conversion for residential and commercial solar installations. The PS series stands out in the market due to its advanced features, innovative technologies, and user-friendly characteristics.

One of the main features of the Xantrex PS2.5 and PS3.0 inverters is their high efficiency rating, typically above 97%. This means that a minimal amount of energy is lost during conversion, allowing users to maximize their solar energy utilization. Additionally, these inverters come with a wide input voltage range, making them versatile and capable of handling various solar panel configurations.

Both models are equipped with advanced MPPT (Maximum Power Point Tracking) technology. This feature optimizes the energy output from solar panels by constantly adjusting the operating point to ensure maximum power is extracted, even in variable weather conditions or partial shading. This capability significantly enhances the overall energy harvest from solar systems.

Another notable characteristic is their compact and lightweight design, which facilitates easy installation and integration into existing systems. The inverters are also designed with robust thermal management solutions, ensuring they operate effectively even in high-temperature environments. This durability extends their lifespan and increases reliability, critical factors for any solar installation.

Xantrex has also prioritized user experience with the PS2.5 and PS3.0 models by providing a built-in monitoring system. Users can access real-time data on energy production, performance metrics, and system status through a user-friendly interface. This connectivity allows for quick troubleshooting and maintenance, thus enhancing the overall efficiency of solar energy systems.

Safety is paramount in the design of these inverters. They meet stringent international safety standards and come equipped with comprehensive protection features, including over-voltage, under-voltage, and short-circuit protection. This ensures the inverter operates safely, protecting both the user and the connected solar array.

In summary, Xantrex Technology's PS2.5 and PS3.0 inverters are engineered with cutting-edge features and technologies that cater to the evolving needs of solar energy users. Their efficiency, adaptability, and focus on safety make them an excellent choice for those looking to invest in renewable energy solutions. As the demand for sustainable energy continues to rise, Xantrex is poised to play a significant role in the market with these innovative inverter solutions.