Standard LED Control Panel

Power Indicator

A green LED labeled UTILITY/SHOREPOWER (INCOMING) lights whenever AC power is supplied to the AC INPUT connectors on the inverter/charger. Throughout this manual, the term “shorepower” refers to the presence of AC power at the AC INPUT connectors, regardless of the source of the power: from the utility grid (power company), a generator, or any other source.

Charger Status Indicator and On/Off Button

The Charger Status Indicator includes four LEDs: a green LED labeled CHARGE; a green LED labeled READY; an amber LED labeled STANDBY; and an amber LED labeled EQUALIZE. A charger ON/OFF button is also provided.

Char ger

Ch a r g e

S t a n d b y

Re a d y

Equal i z e

On/ Of f

Charge LED The green CHARGE LED lights when the Prosine charger is in Bulk or Absorption charging mode. A discussion of the Prosine three-stage charging profile is found in the “Charging Profile” section of this manual (see page 59).

Ready LED The green READY LED lights when the charging cycle has been completed, and the charger is in Float charging mode.

Standby LED The amber STANDBY LED lights when the charger is enabled awaiting AC power. When shorepower becomes available, the charger will begin charging, the STANDBY LED will be extinguished, and the CHARGE LED will be lighted.

Equalize LED The amber EQUALIZE LED lights when the battery equalization has been requested, and the Prosine is in Charge mode. An equalization charge cycle will commence after fully charging the batteries, and both the EQUALIZE LED and the CHARGE LED will flash on-and-off. See “Section 6: Multistage Charging” on page 59 for more information about equalization.

On/Off Button The charger ON/OFF button switches the charger between charger standby mode, On, and Off. In standby mode, the charger begins charging automatically when AC shorepower is available. In charge mode, press and hold this button for 5 seconds to request an equalize charge. Equalize mode will not begin until the batteries are fully charged.

CAUTION Disconnect DC loads on the batteries during equalization to prevent damage to them by the high voltages encountered during equalization. Equalization must be monitored to prevent battery damage. Refer to “Section 6: Multistage Charging” for more details.

10

Prosine 2.5/3.0 Installation & Operation Guide

Page 28
Image 28
Xantrex Technology PS3.0, PS2.5 installation and operation guide Power Indicator, Charger Status Indicator and On/Off Button

PS3.0, PS2.5 specifications

Xantrex Technology has made significant strides in the power electronics sector with the introduction of their PS2.5 and PS3.0 inverter models. These inverters are designed primarily for solar energy applications, offering reliable and efficient power conversion for residential and commercial solar installations. The PS series stands out in the market due to its advanced features, innovative technologies, and user-friendly characteristics.

One of the main features of the Xantrex PS2.5 and PS3.0 inverters is their high efficiency rating, typically above 97%. This means that a minimal amount of energy is lost during conversion, allowing users to maximize their solar energy utilization. Additionally, these inverters come with a wide input voltage range, making them versatile and capable of handling various solar panel configurations.

Both models are equipped with advanced MPPT (Maximum Power Point Tracking) technology. This feature optimizes the energy output from solar panels by constantly adjusting the operating point to ensure maximum power is extracted, even in variable weather conditions or partial shading. This capability significantly enhances the overall energy harvest from solar systems.

Another notable characteristic is their compact and lightweight design, which facilitates easy installation and integration into existing systems. The inverters are also designed with robust thermal management solutions, ensuring they operate effectively even in high-temperature environments. This durability extends their lifespan and increases reliability, critical factors for any solar installation.

Xantrex has also prioritized user experience with the PS2.5 and PS3.0 models by providing a built-in monitoring system. Users can access real-time data on energy production, performance metrics, and system status through a user-friendly interface. This connectivity allows for quick troubleshooting and maintenance, thus enhancing the overall efficiency of solar energy systems.

Safety is paramount in the design of these inverters. They meet stringent international safety standards and come equipped with comprehensive protection features, including over-voltage, under-voltage, and short-circuit protection. This ensures the inverter operates safely, protecting both the user and the connected solar array.

In summary, Xantrex Technology's PS2.5 and PS3.0 inverters are engineered with cutting-edge features and technologies that cater to the evolving needs of solar energy users. Their efficiency, adaptability, and focus on safety make them an excellent choice for those looking to invest in renewable energy solutions. As the demand for sustainable energy continues to rise, Xantrex is poised to play a significant role in the market with these innovative inverter solutions.