Basic Setup Summary
976-0043-01-02 6–3
11C Low Battery Cut Out Vdc 11.0 to 33.9 22.0 32.0 to 67.8 44.0 page6–13
11D LBCO Delay Minutes 01 to 255 15 01 to 255 15 page 6–13
11E Search Watts (SRCH) 00 to 248 08 00 to 248 08 page 6–14
End Menu 11
12 Battery Charging Menu See “12 Battery Charging Menu” on page6–19 for details.
12A Finish Stage SILENT
FLOAT FLOAT SILENT
FLOAT FLOAT page6–19
12B Bulk Volts DC 20.0 to 32.0 28.8 40.0 to 64.0 57.6 page 6–20
12C Float Volts DC 20.0 to 32.0 26.8 40.0 to 64.0 53.6 page6–20
12D Equalize Volts DC 20.0 to 32.0 28.8 40.0 to 64.0 57.6 page 6–20
12E Max Charge Amps AC 01 to 20 20 01 to 20 20 page 6–22
12F Bulk Done Amps AC 00 to 20 10 00 to 20 10 page 6–23
12G EQ Vdc Done Timer 00:00 to 23:50 02:00 00:00 to
23:50 02:00 page6–24
12H Max Bulk/EQ Timer 00:00 to 23:50 05:00 00:00 to
23:50 05:00 page6–25
12I Temp Comp LeadAcid
NiCad LeadAcid LeadAcid
NiCad LeadAcid page 6–25
End Menu 12
13 AC Inputs Menu See “13 AC Inputs Menu” on page6–26 for details.
13A Grid (AC1) Amps AC 00 to 60 60 00 to 60 60 page6–27
13B Gen (AC2) Amps AC 00 to 60 30 00 to 60 30 page6–27
13C Input Upper Limit Vac 125 to 150 130 125 to 150 130 page 6–28
13D Input Lower Limit Vac 80 to 115 110 80 to 115 110 page 6–28
End Menu 13
14 Save/Restore Settings Menu See “14 Save/Restore Settings Menu” on page6–29 for details.
14A Push INV now to save
settings Push INV now to save settings page6–29
14B Push GEN to restore settings Push GEN to restore settings page6–29
Table 6-1Basic Setup Menu Default Settings for the Sine Wave Plus 2524 and 2548 Models
Basic Setup Menus
Sine Wave Plus 2524 Sine Wave Plus 2548
See Page
Range/
Display Default
Range/