Calibration

Allow at least 5 minutes warm-up before commencing calibration.

Access to Calibration Adjustments

All adjustments are on the front panel control board; all the trimmers are adjusted from the reverse side of the board through holes in the board. To gain access to the board it is necessary to remove the top cover.

WARNING!

When the instrument is connected to its supply the removal of covers is likely to expose live parts. The instrument should be disconnected from all voltage sources before it is opened for any adjustment, replacement, maintenance or repair. Capacitors inside the power supply may still be charged even if the power supply has been disconnected from all voltage sources but will be safely discharged about 1 minute after switching off power.

Any adjustment, maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and, if inevitable, shall be carried out only by a skilled person who is aware of the hazard involved.

Remove the 6 side screws and two handle screws to release the top cover.

Component adjustment references are given as Channel A/ Channel B, e.g. VR5/VR105; Channel A is the left-hand output. For single output supplies use Channel A references.

Limits given are for 30V units; values in [ ] brackets are for 18V and 56V models respectively.

Control pcb calibration points (viewed from rear) Equipment Required

A 5½ digit multimeter with better than 0·05% accuracy on dc volts and better than 0·1% accuracy on dc current (to 5A); alternatively use a precision shunt for current measurement.

Use a rheostat or other high power load arrangement to provide up to 2A load at 30V [3A/18V,1A/56V].

Voltage Calibration

Connect the DMM (set to Volts) across the output. Set voltage and current controls to minimum. Switch output ON (Check LED is on) and check for a reading of 00·0V ± 0·1V on the Volts display and DMM; check the Amps display reads 0·00 ± 0·01A.

Set voltage and current controls to maximum. Adjust VR5/VR105 (maximum output volts) for a reading of 30·8 [18·3, 56·4] on the DMM. Adjust VR6/VR106 (measured output volts) until the Volts display matches the reading on the external DMM.

Switch output OFF. Adjust VR10/110 (preset volts) until the Volts display shows 30·8 [18·3, 56·4].

10

Page 11
Image 11
Xantrex Technology XPL 30-1, XPL 30-2D, XPL 18-3, XPL 56-1 manual Access to Calibration Adjustments, Voltage Calibration

XPL 30-2T, XPL 30-1, XPL 30-2D, XPL 18-3, XPL 30-2 specifications

Xantrex Technology has established itself as a leader in the power solutions market, particularly with its innovative line of XPL inverter series. This series includes models XPL 56-1, XPL 30-2, XPL 18-3, XPL 30-2D, and XPL 30-1, each designed with unique features and characteristics to meet various power needs.

The XPL 56-1 is a powerhouse inverter known for its high output capacity, making it ideal for larger applications such as recreational vehicles or off-grid systems. With a robust design and advanced thermal management technology, this model can sustain heavy loads while ensuring reliability and efficiency. Its compact structure and lightweight design facilitate easy installation and flexibility in various setups.

The XPL 30-2 and XPL 30-2D models are tailored for users looking for a balance of power and portability. Both are equipped with advanced pure sine wave output, ensuring a clean and stable power supply that protects sensitive electronics. The XPL 30-2D variant features dual output options, allowing simultaneous powering of multiple devices, enhancing versatility for users in diverse environments.

For those with smaller power requirements, the XPL 18-3 is the perfect choice, offering a smaller footprint while still delivering robust performance. This model is optimized for efficiency, enabling longer battery life in applications like camping or marine use. Its user-friendly interface allows for easy monitoring and control, making it a favorite among casual users.

The XPL 30-1 stands out for its adaptability, supporting a range of input voltages and providing adjustable output settings. This model is particularly suited for industrial applications, thanks to its rugged construction and ability to withstand harsh environments. Advanced safety features, including overload protection and short-circuit prevention, ensure that both the inverter and connected devices remain safe during operation.

In summary, the Xantrex XPL inverter series provides cutting-edge technology and versatile solutions for various power demands. Each model is engineered with specific features to cater to different user needs, ensuring reliable power during outdoor adventures, industrial operations, or off-grid living. With Xantrex’s commitment to quality and innovation, the XPL series continues to set the standard in portable and stationary power systems.