TROUBLESHOOTING
If the unit fails to operate normally, check the following points to determine whether the fault can be corrected by the simple measures suggested. If it cannot be corrected, or if the fault is not listed in the SYMPTOM column, disconnect the power cord and contact your authorized YAMAHA dealer or service center for help.
SYMPTOM | CAUSE | REMEDY |
The unit fails to turn on when the POWER | Power cord is not plugged in or is not | Firmly plug in the power cord. |
switch is pressed. | completely inserted. |
|
|
|
|
No sound or no picture. | Incorrect output cord connections. | Connect the cords properly. If the problem |
|
| persists, the cords may be defective. |
|
|
|
| Appropriate input source is not selected. | Select an appropriate input source with the |
|
| INPUT selector. |
|
|
|
| Power amp connections are not secure. | Plug in the connection cords properly. |
|
|
|
Only one side speaker outputs the sound. | Incorrect setting of the BALANCE control. | Adjust it to the appropriate position. |
|
|
|
Sound “hums”. | Incorrect cord connections. | Firmly connect the audio plugs. If the |
|
| problem persists, the cords may be defective. |
|
|
|
| No connection from the turntable to the GND | Make the GND connection between the |
| terminal. | turntable and this unit. |
|
|
|
Sound level is low. | The LOUDNESS control is functioning | Set the LOUDNESS control to the FLAT |
| (for | position. |
|
|
|
| The MUTING switch is ON. | First, turn the volume control to the full left. |
|
| Then, turn the MUTING switch OFF with the |
|
| remote control transmitter and adjust the |
|
| volume. |
|
|
|
The sound from the MC cartridge is too | PHONO switch is set to MM. | Set this switch to MC. |
low |
|
|
|
|
|
Using the BASS, TREBLE, BALANCE and | The PURE DIRECT switch is ON. | The PURE DIRECT switch must be switched |
LOUDNESS (for |
| OFF to use those controls. |
not affect the tone. |
|
|
|
|
|
The remote control transmitter does not | Direct sunlight or lighting (of an inverter type | Change position of the main unit. |
work. | of flourescent lamp etc.) is striking the |
|
| remote control sensor of the main unit. |
|
|
|
|
The distance or range within which the | The batteries of this remote control | Replace the batteries with new ones. |
remote control transmitter can be used | transmitter are too weak. |
|
decreases. |
|
|
|
|
|