References
Other Functions Connecting to an
External Device
Audio I/O
Connection
Connecting to
a Computer
Controls and
Connectors
Introduction to
the DME Satellite
Foreword
DME8i-ES/DME8o-ES/DME4io-ES Owner’s Manual 31
Initializing the DME Satellite
You can initialize the DME Satellite internal memory.
Select one of the following initialization types:
Initialize DME:
All scenes, preset parameter settings and WAVE files except components and files saved via the File Storage func-
tion will be deleted. The Utility settings will be set to default values.
Delete All Data:
All stored component, scene, preset parameter settings, WAVE files, and files saved via the File Storage function
will be deleted. The Utility settings will be set to default. Use this initialization type if the internal data is damaged
or corrupted. After initialization, transfer necessary components from DME Designer.
1. While the DME Satellite is turned off, set the dip switch on the rear panel to the following
position, then turn on the power to the unit.
Four [PEAK] indicators on the upper row on the front panel light up during the initialization process. Four
[SIGNAL] indicators on the lower row of the front panel flash when the initialization process is complete. Four
[PEAK] indicators on the lower row of the front panel flash if the initialization process fails.
2. When initialization is complete, reset the dip switch to its previous position (page 16),
then turn off and on the power to the unit.
Other FunctionsDo NOT turn off the power to the DME Satellite during the initialization process to prevent possible
damage to the device.
Be sure to reset the dip switch to the previous position to prevent possible damage to the device.
RS-232C
RS-422
Initialize DME:
Delete All Data:
RS-232C
RS-422
CAUTION
CAUTION