Yamaha EF1600, EF2600, YG2600 owner manual G.F.C.I. RECEPTACLE for YG2600

Models: EF1600, EF2600, YG2600

1 41
Download 41 pages 28.49 Kb
Page 16
Image 16
G.F.C.I. RECEPTACLE (for YG2600)

1

w

763-083

3

763-060

AE00848

G.F.C.I. RECEPTACLE (for YG2600)

The G.F.C.I. (Ground Fault Circuit Interrupter) 1 shuts off power to the protected receptacles if a ground fault (electrical leak) is detected.

If the reset button 2 pops out 3, the equipment plugged into the receptacle may be faulty. If this hap- pens, check the equipment carefully. If the equipment appears to be in good condition, press the reset button firmly until a click is heard. This will restore power. If the reset button pops out again, unplug the equipment immediately. Have the equipment inspected and repaired by a qualified repairperson before attempting to use it again.

w

TO REDUCE THE CHANCE OF ELECTRICAL SHOCK:

9Do not attempt to operate equipment if the ground fault circuit interrupter reset button pops out repeatedly during use.

9Test the ground fault circuit interrupter during the pre-operation checks according to the maintenance instructions on page 25.

9Remember that only receptacles labeled “Ground Fault Protected” have ground fault circuit interrupter protection.

– 11 –