Ground (earth) Lead

Diameter:

0.12mm (0.005 in)/ampere

EX;

10 Ampere 1.2 mm (0.05 in)

 

 

 

AE01181

 

 

 

CONNECTION NOTES

1

 

 

9 Avoid connecting the generator to commercial

 

 

power outlet.

 

 

 

 

 

 

1 Correct

 

 

 

2 Incorrect

2

 

 

AE00091

 

 

CONNECTION

 

 

 

 

 

 

w

 

 

 

 

Before the generator can be connected to a build-

 

 

 

ing’s electrical system, a licensed electrician must

 

 

 

install an isolation (transfer) switch in the build-

1

 

 

ing’s main fuse box. The switch is the connection

 

 

 

point for generator power and allows selection of

 

 

 

generator or main line power to the building. This

 

 

 

will prevent the generator from charging the main

 

 

 

power line (backfeeding) when the main power sup-

 

 

 

ply has failed or has been turned off for line repair.

 

741-122

 

Backfeeding can electrocute or injure line mainte-

 

 

 

nance personnel. Also, generator and building

 

 

 

electrical system damage can occur when normal

 

 

 

 

 

operating power returns if unit is used without an

 

 

 

isolation switch.

 

 

 

 

 

AE00086

EXTENSION CORD NOTES

9When using an extension cord, its total length should not exceed

60 meters for cross section of 1.5 mm square

and

100 meters for cross section of 2.5 mm square.

9This extension cord should be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to withstand mechanical stresses.

– 7 –