q
w
w
q
AE00111
OIL WARNING SYSTEM
When the oil level falls below the lower level, the engine stops automatically. Unless you refill with oil, the engine will not start again.
NOTE:
If the engine stalls or does not start, turn the engine switch to “ON” position and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and restart.
AE00124
ENGINE SWITCH
The engine switch controls the ignition system.
17 “ON”
Ignition circuit is switched on.
The engine can be started.
25 “STOP”
Ignition circuit is switched off.
The engine will not run.
AE00780
DC PROTECTOR
The DC protector turns off automatically when the load exceeds the generator rated output.
cC
Reduce the load to the specified generator rated output if the DC protector turns off. If it turns off again, consult a Yamaha dealer.
NOTE:
Press to reset the DC protector.
1 I “ON”
2 3 “OFF”
AE01179
TWIN TECH
(TERMINAL FOR CONNECTING SPECIAL CABLES FOR PARALLEL RUNNING )
This is the terminal for connecting special cables for parallel running of two EF2400iS. The parallel running requires two EF2400iS and the special cables. (The rated output in parallel running is 3.6 kVA and the rated current is 30.0 A.)
The handling, operation procedure and the notes on usage are described in the PARALLEL RUNNING KIT OWNER’S MANUAL included in the Parallel Running Kit. Consult a Yamaha dealer for this Parallel Running Kit.
– 9 –