TX6n/5n/4n Reference Manual
16
Panel Operations
This shows the input/output levels of the audio signal, and the status of the power supply. As when you’re in the
HOME screen, you can use encoders A/B to adjust the attenuation of each channel.
To access the METER screen, access the HOME screen and press the left-most function button (METER). You can
change the meter type by using the left-most function button (PREV) and right-most function button (NEXT).
qLevel meter
This shows the name of the currently selected meter type and the meter for each channel. The “<” “>” beside the meter are
threshold values.
• When the input level from an analog input jack or slot exceeds the maximum value of digital signal, the top segment of
the meter will light.
wGain
This indicates the currently specified gain for each channel. The gain can be adjusted in the MENU screen (page 24).
eAttenuation
This indicates the current attenuation for each channel. You can use encoders A/B to adjust the attenuation for each channel.

Meter types that can be shown

The display units can be specified in the SETTING screen (page 17).
METER Screen
Meter type Display unit Explanation
ANA INPUT VOLTAGE dBFS, dBu, V Input level from the analog jack
SLOT INPUT VOLTAGE dBFS Input level from the slot
SP OUTPUT VOLTAGE dBu, V Speaker output level
SP OUTPUT POWER W Speaker output power
SP OUTPUT IMPEDANCE Speaker output impedance
SLOT OUTPUT METER dBFS Slot output level
THERMAL % Heat sink temperature of amplifier section
e
ww
eq
NOTE