268 Chapter 20—Remote Control
DM2000 Version 2—Owner’s Manual
Controlling AD8HR/AD824s from the DM2000
Connected AD8HR/AD824s are controlled from the HA Control page.
1Use the SELECTED CHANNEL PHASE/INSERT [DISPLAY] button to select the
HA Control page.
2Use the cursor buttons to select the ID of the HA (AD8HR/AD824) that you
want to control, and then press [ENTER].
3Use the rotary controls to set the gain of each HA channel, and use the +48V
buttons to turn phantom power on or off for each channel.
If you connected an AD8HR, you can monitor the +48V MASTER switch on/off status on
the AD8HR.
4If you connected an AD8HR, turn the rotary controls to set the HPF (high
pass filter) cutoff frequency for each HA channel, and use the HPF buttons
to turn HPF on or off for each channel.
All parameter settings, excluding the phantom power on/off setting, will be saved as part of
a scene.