Effects Parameters 325
DM2000—Owner’s Manual
MULTI FILTER

Two input, two output 3-band multi-filter (24 dB/octave).

FREEZE

One input, one output basic sampler.

Parameter Range Description
TYPE 1 HPF, LPF, BPF Filter 1 type: high pass, low pass, band pass
TYPE 2 HPF, LPF, BPF Filter 2 type: high pass, low pass, band pass
TYPE 3 HPF, LPF, BPF Filter 3 type: high pass, low pass, band pass
FREQ. 1 28.0 Hz–16.0 kHz Filter 1 frequency
FREQ. 2 28.0 Hz–16.0 kHz Filter 2 frequency
FREQ. 3 28.0 Hz–16.0 kHz Filter 3 frequency
LEVEL 1 0–100 Filter 1 level
LEVEL 2 0–100 Filter 2 level
LEVEL 3 0–100 Filter 3 level
RESO. 1 0–20 Filter 1 resonance
RESO. 2 0–20 Filter 2 resonance
RESO. 3 0–20 Filter 3 resonance
Parameter Range Description
REC MODE MANUAL, INPUT
In MANUAL mode, recording is started by pressing the REC and
PLAY buttons. In INPUT mode, Record-Ready mode is engaged by
pressing the REC button, and actual recording is triggered by the
input signal.
REC DLY –1000 to +1000 ms
Recording delay. For plus values, recording starts after the trigger is
received. For minus values, recording starts before the trigger is
received.
TRG LVL –60 to 0 dB Input trigger level (i.e., the signal level required to trigger recording
or playback)
TRG MASK 0–1000 ms Once playback has been triggered, subsequent triggers are ignored
for the duration of the TRG MASK time.
PLY MODE MOMENT, CONTI.,
INPUT
In MOMENT mode, the sample plays only while the that the PLAY
button is pressed. In CONT mode, playback continues once the
PLAY button has been pressed. The number of times the sample
plays is set using the LOOP NUM parameter. In INPUT mode, play-
back is triggered by the input signal.
START 1
1. 0.0–5941.0 ms (fs=44.1 kHz), 0.0 ms–5458.3 ms (fs=48 kHz), 0.0–2970.5 ms (fs=88.2 kHz),
0.0 ms–2729.2 ms (fs=96 kHz)
Playback start point in milliseconds
END 1Playback end point in milliseconds
LOOP 1Loop start point in milliseconds
LOOP
NUM 0–100 Number of times the sample plays
START
[SAMPLE] 0–262000 Playback start point in samples
END
[SAMPLE] 0–262000 Playback end point in samples
LOOP
[SAMPLE] 0–262000 Loop start point in samples
PITCH –12 to +12 semitones Playback pitch shift
FINE –50 to +50 cents Playback pitch shift fine
MIDI TRG OFF, C1–C6, ALL PLAY button can be triggered by using MIDI Note on/off messages.