Yazoo/Kees ZCBI48181 REPLACING BATTERY See Fig, To Attach Jumper Cables, Service And Adjustment

Models: ZCBI48181

1 40
Download 40 pages 29.62 Kb
Page 31
Image 31
TO ATTACH JUMPER CABLES

SERVICE AND ADJUSTMENT

TO ATTACH JUMPER CABLES

Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis.

Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery.

Connect the other end of the BLACK cable to a good CHASSIS GROUND, away from the fuel tank and battery.

TO REMOVE CABLES, REVERSE ORDER

BLACK cable first from chassis and then from the fully charged battery.

RED cable last from both batteries.

REPLACING BATTERY (See Fig. 18)

TO REMOVE CABLES, REVERSE ORDER WARNING

Do not short battery terminals by allowing a wrench or any other object to contact both terminals at the same time. Before connecting battery, remove metal brace- lets, wristwatch bands, rings, etc.

Positive terminal must be connected first to prevent sparking from accidental grounding.

Lift Seat and rotate forward.

Open terminal access doors.

Using two 1/2" wrenches disconnect BLACK battery cable then RED battery cable.

Using 7/16" wrench, remove terminal guard.

Carefully remove the battery from the mower.

Install new battery with terminals in the same position as the old battery.

Reinstall terminal guard

First connect RED battery cable to positive (+) battery terminal with hex bolt and hex nut.

Connect BLACK grounding cable to negative (-) battery terminal with remaining hex bolt and hex nut.

Tighten securely.

Close terminal access doors.

Lower seat.

TERMINAL

 

GUARD

 

 

TERMINAL

 

ACCESS

 

DOORS

FIGURE 18

CZ-22

 

31

Page 31
Image 31