SITE REQUIREMENTS

SITE REQUIREMENTS

WALLS ADJACENT TO HEARTHS

Location of hearth or Solid fuel

Solid, non combustible material

 

 

cooker

 

 

Thickness (W)

height (A)

 

 

 

 

Where the hearth abuts a wall and the solid

200mm

At least 300mm above the solid fuel

fuel cooker is not more than 50mm from the

cooker and 1200mm above the

wall

 

hearth(Use the largest value)

Where the hearth abuts a wall and the

75mm

At least 300mm above the solid fuel

appliance is more than 50mm but not more

cooker and 1200mm above the hearth

than 300mm from the wall

 

(Use the largest value)

Where the hearth does not abut a wall and

75mm

At least 300mm above the hearth

is no more than 150mm from the wallSee

note below

 

 

Note: there is no requirement for protection the wall where C is more than 150mm