2.COMMISSIONING

INSTALLATION INSTRUCTIONS

1.11 Rear or side flue pipe installation

5” Flue Pipe

(Stovax Part No. 4501)

5” Tee

(Stovax Part No. 4516)

1.12Connect a tee (Stovax part no 4516 (5” pipe)) by inserting it into the flue spigot and sealing using fire cement. The cap supplied with the tee is used as the cleaning access.

1.13Side flue installation will require the use of an extension flue pipe to enable correct fitting of tee (Stovax part No. YM-CKADAP).

1.14Top flue pipe installation

5” Flue Pipe

(Stovax Part No. 4501)

1.15Connect a flue pipe 612mm long (Stovax part no 4501 (5” pipe)) by inserting it into the flue spigot and sealing using fire cement.

2.COMMISSIONING

2.1Before lighting the Solid fuel cooker, check the following items:

a)Fit of internal parts (firegrate, firebricks, baffles, and log retainer).

b)Door alignment, seals and catch operation.

c)Operation of air controls.

d)Operation of riddling grate system.

e)Check no items have been left in the warming drawer, oven, firebox and ashpan.

2.2If there are any problems with the fit or operation of any of these items this should be corrected before continuing with the commissioning of the Solid fuel cooker.

2.3Carry out a final smoke draw test, by first warming the flue with a blowlamp, or similar, for about 10 minutes. Then place a smoke pellet on the centre of the grate, with the air controls open, and close the door. Smoke should now be drawn up the flue and be seen to exit from the flue terminal. This test should be completed with all doors and windows in the room where the Cooker is fitted closed. Should this test fail the suitability of the flue system and ventilation should be re-checked.

2.4Light the appliance and gently allow the temperature to increase slowly to operating levels. Check that no combustion products are entering the room. When the Cooker has reached a steady operating condition open the main firedoor and carry out a spillage test with a smoke match or pellet around the door opening.

2.5If excessive spillage does occur allow the appliance to cool and re-check the suitability of the flue system and ventilation.

2.6Explain the safe operation of the cooker and the use of the controls to the user, along with the need to only use suitable fuels. Also explain the cleaning and routine maintenance requirements.

2.7Explain the requirements to use a suitable protection when children, elderly or infirm persons may be near the appliance.

2.8Record dealer/supplier details and installer details in user instructions.