HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

E1RA060S(25,46)

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

G2FD060(S,H)24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

ENTERING

ENTERING

 

 

 

 

 

 

 

 

 

 

1600

 

 

1800

 

 

2000

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

60

63.6

5.09

3.67

61.9

4.98

3.64

60.1

4.87

3.62

60

 

 

 

 

 

 

 

 

 

 

70

64.8

5.33

3.56

63.5

5.18

3.59

62.2

5.04

3.62

 

 

 

 

 

 

 

 

 

 

 

 

80

65.9

5.60

3.45

65.1

5.39

3.54

64.2

5.20

3.62

 

 

 

 

 

 

 

 

 

 

 

 

60

56.9

4.15

4.03

55.7

4.02

4.06

54.4

3.90

4.10

47

 

 

 

 

 

 

 

 

 

 

70

58.3

4.62

3.70

58.0

4.54

3.75

56.3

4.35

3.80

 

 

 

 

 

 

 

 

 

 

 

 

80

59.7

5.19

3.38

59.0

5.03

3.44

58.2

4.88

3.50

 

 

 

 

 

 

 

 

 

 

 

 

60

54.5

4.05

3.95

53.3

3.93

3.97

52.0

3.81

4.00

40

 

 

 

 

 

 

 

 

 

 

70

53.7

4.41

3.57

53.4

4.32

3.63

53.2

4.22

3.69

 

 

 

 

 

 

 

 

 

 

 

 

80

52.9

4.87

3.19

53.6

4.78

3.29

54.3

4.71

3.38

 

 

 

 

 

 

 

 

 

 

 

 

60

49.6

3.89

3.74

49.8

3.80

3.84

49.9

3.72

3.93

30

 

 

 

 

 

 

 

 

 

 

70

47.7

4.18

3.34

48.0

4.10

3.44

48.4

4.02

3.53

 

 

 

 

 

 

 

 

 

 

 

 

80

45.8

4.57

2.94

46.3

4.47

3.04

46.8

4.39

3.13

 

 

 

 

 

 

 

 

 

 

 

 

60

40.6

3.56

3.34

41.0

3.51

3.42

41.3

3.46

3.50

17

 

 

 

 

 

 

 

 

 

 

70

38.8

3.86

2.94

39.2

3.80

3.02

39.7

3.74

3.11

 

 

 

 

 

 

 

 

 

 

 

 

80

36.9

4.26

2.54

37.5

4.18

2.63

38.0

4.10

2.71

 

 

 

 

 

 

 

 

 

 

 

 

60

36.3

3.53

3.01

36.7

3.46

3.11

37.1

3.38

3.21

10

 

 

 

 

 

 

 

 

 

 

70

34.3

3.82

2.63

34.7

3.74

2.72

35.2

3.67

2.81

 

 

 

 

 

 

 

 

 

 

 

 

80

32.2

4.19

2.25

32.7

4.12

2.33

33.2

4.05

2.40

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

 

 

 

 

 

MA20DN2,4

FC/MC60D3X

1.00

1.00

1.00

 

 

 

 

 

N1AHD2046

G2FD060(S,H)24

1.00

1.00

1.00

 

 

 

 

 

AHP/SHP60D3X

1.01

1.03

0.98

 

 

 

 

 

F2FP060

1.01

1.03

0.98

 

 

 

 

 

G1FA060S21,24

1.00

1.00

1.00

 

 

 

 

 

G1UA060S21,24

1.00

1.00

1.00

 

 

 

 

 

FC/MC/PC/UC60*3X

1.00

1.00

1.00

 

 

 

 

 