York 060, 090, 036-048 warranty Dimensions, Physical and Electrical Data

Models: 060 036-048 090

1 16
Download 16 pages 6.12 Kb
Page 2
Image 2
Physical and Electrical Data

279104-YTG-B-0307

Physical and Electrical Data

 

MODEL

E1RA036S25

E2RA048S25

E1RA060S25

E1RA036S46

E2RA048S46

E1RA060S46

Unit Supply Voltage

 

 

208/230-3-60

 

 

460 - 3 - 60

 

Normal Voltage Range 1

 

187 to 252

 

 

432 to 504

 

Minimum Circuit Ampacity

15.0

18.9

24.5

8.0

10.1

12.0

Max. Qvercurrent Device Amps 2

25

30

40

15

15

20

Compressor Type3

 

Inertia

ScrollD

ScrollC

Inertia

ScrollD

ScrollC

Compressor Amps

 

Rated Load

10.9

14.1

18.6

5.8

7.0

9.0

 

 

 

Locked Rotor

78

125

128

40

55

63

Crankcase Heater

 

 

Yes

No

No

Yes

No

No

Fan Motor Amps

 

Rated Load

1.4

1.3

1.3

.8

.7

.8

Fan Diameter Inches

 

 

18

22

24

18

22

24

Fan Motor

 

 

Rated HP

1/4

1/4

1/4

1/4

1/5

1/4

 

 

 

Nominal RPM

1,100

850

850

1,100

825

850

 

 

 

Nominal CFM

2,750

3,500

3,100

2,750

3,500

3,100

Coil

Face Area Sq. Ft.

12.58

19.65

18.00

12.58

19.65

18.00

 

Rows Deep

1

1

2

1

1

2

 

Fin / Inches

14

13

14

14

13

14

Liquid Line

Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

7/8

7/8

3/4

7/8

7/8

Unit Charge (Lbs. - Oz.) 4

5 - 12

8 - 3

11 - 3

5 - 12

8 - 3

11 - 3

Charge Per Foot, Oz.

 

.68

.70

.70

.68

.70

.70

Operating Weight Lbs.

178

232

243

178

232

243

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker.

3.All scrolls listed with a superscript “D” are Danfoss scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.

4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon

Crequest.

 

 

DIMENSIONS

 

 

 

 

 

 

Unit

Dimensions

 

Refrigerant

A

 

 

Connection

 

Model

(Inches)

 

 

 

 

Service Valve Size

 

 

 

 

 

 

 

 

 

A1

B

C

Liquid

Vapor

 

 

036

25

35

23

 

3/4”

 

 

048

33

37

27

3/8”

7/8”

 

B

060

26

43

32

 

7/8”

 

 

1.

Including fan guard.

 

 

 

2

Unitary Products Group

Page 2
Image 2