York 48, 36, 60 Factory-Installedoptions, Field-Installedaccessories, Unit Cutaway, YTG-A-0506

Models: 48 60 36

1 44
Download 44 pages 16.54 Kb
Page 5
Image 5
FIGURE 1 - UNIT CUTAWAY

255040-YTG-A-0506

 

 

20 GAUGE ALUMINIZED

POWER VENTOR MOTOR

 

 

 

 

 

STEEL TUBULAR HEAT

WITH POST PURGE CYCLE

 

 

 

 

 

EXCHANGER

 

 

DIRECT OR

 

HIGH EFFICIENCY

 

BELT DRIVE

 

ECONOMIZER

 

COMPRESSOR

BLOWER

 

HOOD

 

 

 

 

 

COPPER TUBE/

ALUMINUM FIN

CONDENSING

COIL

SLIDE-IN

ECONOMIZER

 

FULL PERIMETER

 

BASE RAILS WITH

SIDE RETURN

FORKLIFT SLOTS

AIR DUCT OPENING

AND LIFTING HOLES

BOTTOM

 

KNOCKOUT FOR SIDE

 

GAS SUPPLY ENTRY

RETURN

 

 

 

AIR DUCT

3/4” PVC FEMALE

 

OPENING

CONDENSATE DRAIN

LOW VOLTAGE CONTROL

 

 

BOARD

 

KNOCKOUTS FOR

 

 

SIDE POWER AND

 

 

CONTROL ENTRY

 

FIGURE 1 - UNIT CUTAWAY

FACTORY-INSTALLED OPTIONS

SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

PHENOLIC COATED CONDENSER COILS - Special coating process that utilizes Technicoat 10-1TMpro- cesses. Coating is applied by total immersion of the com- plete coil for maximum protection.

BELT DRIVE INDOOR FAN - Includes belt drive indoor fan and motor with unit access for belt adjustment and service.

FIELD-INSTALLED ACCESSORIES

SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in /plug-in damper assembly with a 2- position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down.

The rain hood is painted to match the basic unit and must be field assembled before installing.