TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS 13 SEER
AY012MA321 THRU 036
(1 THRU 3 NOMINAL TONS, 1 PH)
|
|
|
|
|
| E D | T O | A R I |
|
|
| ||
|
|
|
|
| I |
|
| AS |
| ||||
|
|
|
| TIF |
|
|
|
|
|
|
| ||
|
|
| ER |
|
|
|
|
|
|
|
| C |
|
|
|
| C |
|
|
|
|
|
|
|
| M | |
|
|
|
|
|
|
|
|
|
|
|
| O |
|
|
|
| R |
|
|
|
|
| AI | R- |
| P | |
|
| E |
|
|
|
|
|
|
| L | |||
| R |
|
| Y |
|
|
|
|
| CO | Y | ||
U |
|
|
| A | R |
|
|
|
|
|
| IT | N |
T |
|
| N |
|
|
|
|
|
|
|
| I |
|
C |
|
|
|
|
|
|
|
|
|
| O | G | |
A |
|
| U |
|
|
|
|
|
|
|
| NI | W |
F |
|
|
|
|
|
|
|
|
|
|
| N | I |
U |
|
|
|
|
|
|
|
|
|
|
| G | T |
N |
|
|
|
|
|
|
|
|
|
|
|
| H |
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
M |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
| C |
|
| E |
|
| T |
|
| OF |
|
|
|
| E |
|
|
| Q U I P M EN |
|
|
| |||
|
|
| RT |
|
|
|
|
|
| S |
| ||
|
|
| A |
| IF I | CA T I ON | S ECT | ION |
| ||||
|
|
|
| R I | S T | A N DAR D | 21 |
| |||||
|
|
|
|
|
|
|
|
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
| ISO 9001 |
LISTED | Certified Quality |
Management System |
Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
Additional rating information can be found at www.ari.org/aridirectory.
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a versa- tile system of air conditioning. It is designed to be custom- matched with one of UPG’s complete line of evaporator sections, each designed to serve a specific function.
WARRANTY
FEATURES
•QUALITY CONDENSER COILS - The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for increased efficiency and corrosion protection.
•COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a coated steel coil guard.
•PROTECTED COMPRESSOR - Compressors are internally protected against high pressure and temperature. This is accom- plished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesir- able operating conditions occur. A liquid line
•DURABLE FINISH - The cabinet is made of
•LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof.
•TOP DISCHARGE - The warm air from the top mounted fan is blown away from the structure and any landscaping. This allows compact location on
•LOW OPERATING SOUND LEVEL - The upward air flow car- ries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the condenser coil muffle the normal fan motor and compressor operating sounds.
•LOW MAINTENANCE - Long life permanently lubricated motor- bearings need no annual servicing.
•EASY SERVICE ACCESS - Fully exposed refrigerant connec- tions and a single panel covering the electrical controls make for easy servicing of the unit.
•SECURED SERVICE VALVES - Secured
•U.L. AND C.U.L. LISTED - Approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE