York AY012MA321 Typical Installation, Typical Field Wiring, YTG-D-0606, Unitary Products Group

Models: AY012MA321

1 16
Download 16 pages 4.59 Kb
Page 10
Image 10
TYPICAL INSTALLATION

246814-YTG-D-0606

TYPICAL INSTALLATION

MINIMUM 24” SERVICE ACCESS

CLEARANCE ON ONE SIDE

48” OVERHEAD CLEARANCE

THERMOSTAT

WEATHERPROOF

DISCONNECT

SWITCH

 

NEC CLASS 1 WIRING

12” CLEARANCE

TO FURNACE OR

AROUND PERIMETER

AIR HANDLER

 

TERMINAL BLOCK

 

NEC CLASS 2 WIRING

 

TO INDOOR COIL

NOTE:ALL OUTDOOR WIRING

MUST BE WEATHERPROOF.

CONTROL ACCESS PANEL

SEAL OPENING(S) WITH

 

 

PERMAGUM OR EQUIVALENT

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)

POWER WIRING

CONTROL WIRING

FACTORY WIRING

FURNACE OR AIR HANDLER TERMINAL BLOCK

GND.

LUG

CONTACTOR TERMINALS

COIL

*TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

C Y R G W

Y R G W

*

CONDENSING UNIT

ROOM THERMOSTAT

 

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

10

Unitary Products Group

Page 10
Image 10