Additional R-22 Charge / TXV for Various Matched Systems (continued)

 

Outdoor Unit

 

AY012MA321

AY018MA321

AY024MA321

AY030MA321

AY036MA321

Required TXV

 

1TVM2A1

1TVM2A1

1TVM2A1

1TVM2A1

1TVM2A1

Factory R-22 Charge, lbs-oz

2 - 14

2 - 14

3 - 6

3 - 14

3 - 8

Indoor Coil1

Coil Orifice2

 

TXV Kit3 - Additional Charge, Oz

 

AHP18B3X

2A + 0

2A + 0

AHP24B3X

2A + 0

2A + 0

AHP36C3X

2A + 0

AHP42C3X

2A + 9

G2FD024(S,H)14,17

61

2A + 0

2A + 0

G2FD030(S,H)17

65

2A + 0

2A + 0

2A + 0

G2FD035(S,H)14

65

2A + 0

2A + 0

2A + 0

G2FD036(S,H)17

75

2A + 0

2A + 0

G2FD036(S,H)21

75

2A + 0

G2FD042(S,H)21

78

2A + 0

2A + 9

G2FD046(S,H)17

78

2A + 0

2A + 9

G2FD048(S,H)21,24

84

2A + 9

G4FD024H14T2A

0

0

G4FD024H17T2A

0

0

G4FD030H17T2A

0

0

0

G4FD035H14T2A

0

0

0

G4FD036H17T2A

0

0

G4FD036H21T2A

0

G4FD042H21T2A

0

9

G4FD046H17T2A

0

9

G4FD048H21T2A

9

G4FD048H24T2A

9

G1HA024H14

61

2A + 0

2A + 0

G1HA036H14

75

2A + 0

2A + 0

G1NA030S17K

63

2A + 0

2A + 0

G1NA030S21M

63

2A + 0

2A + 0

G1NA036S17J

67

2A + 0

G1NA036S17L

71

2A + 0

G1NA036S21C

67

2A + 0

G1NA042S24W

84

2A + 9

G1NA048S21D

78

2A + 0

G1FA/G1UA030S14

65

2A + 0

2A + 0

G1FA/G1UA036S17,2

73

2A + 0

2A + 0

2A + 0

G1FA/G1UA048S17

84

2A + 0

2A + 9

G1FA/G1UA048S21

84

2A + 9

G4FA030S14T2A

0

0

G4FA036S17T2A

0

0

0

G4FA036S21T2A

0

0

0

G4FA048S17T2A

0

9

G4FA048S21T2A

9

F2RP/F2FP024

61

2A + 0

F2RP/F2FP030

65

2A + 0

F2RP/F2FP042

78

2A + 9

F4FP024H06T2A

2A + 0

F4FP030H06T2A

2A + 0

F4FP042H06T2A

2A + 9

FOOTNOTES:

* This system does not achieve 13 SEER

1.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit #6918A5011

2.These orifices are factory mounted in the flow device of each indoor coil

3.A TXV kit must be used with these coils to obtain system performance (2A, 2B, and 2C indicate 1TVM series)

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing.

2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.

4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

4