| ECONOMIZER / MOTORIZED DAMPER, | |
| FIXED OUTDOOR INTAKE AIR AND | ||
| POWER EXHAUST RAIN HOODS | ||
| DISCONNECT SWITCH | ||
BLOWER | (See detail "Y") | ||
LOCATION | |||
ACCESS | COMPRESSOR | ||
| ACCESS | ||
|
| ||
BLOWER MOTOR |
| (See detail "X") |
ACCESS |
|
|
|
|
BLOWER |
|
|
| OPTIONAL COIL |
COMPARTMENT |
|
|
| GUARD KIT |
ACCESS |
|
|
| |
(Auxiliary) |
|
|
| |
|
|
| ||
|
|
|
| |
DOT PLUG |
|
|
|
|
(For pressure |
|
|
|
|
Drop Reading) |
|
|
| CONDENSER |
|
|
|
| |
|
|
|
| COILS |
|
| 21" |
|
|
|
| 5" |
|
|
|
|
|
| |
FRONT |
|
|
| |
|
|
|
| |
VIEW | ELECTRIC HEAT | 92" |
| |
ACCESS |
|
| (A) | |
|
|
|
| |
| CONTROL BOX |
| CONTROL WIRING | |
| ACCESS |
|
| ENTRY |
|
|
|
| |
| 35" | BOTTOM SUPPLY | (B) | |
|
| |||
|
| POWER WIRING | ||
|
|
| AND RETURN | |
|
|
| ENTRY | |
|
|
| AIR OPENINGS | |
|
|
|
| |
|
|
| (See Note) |
|
|
|
|
| |
| RETURN |
|
| |
|
|
| ||
|
| AIR |
| |
|
| 33" |
|
|
|
| SUPPLY |
|
|
|
| AIR |
|
|
|
|
|
| |
UNIT BASE WITH RAILS |
|
|
| (B) |
Shown separately to illustrate |
|
|
| |
|
|
| POWER WIRING | |
Bottom Duct openings and Power |
|
|
| |
|
|
| ENTRY | |
Connection locations |
|
|
| |
|
|
|
| |
|
|
|
| (A) |
|
|
| CONTROL WIRING | |
|
|
| ENTRY | |
NOTE: |
|
|
| |
|
|
|
| |
For curb mounted units, refer to the curb hanger |
|
| ||
dimensions of the curb for the proper size of the |
|
| ||
| ||||
supply and return air duct connections. |
| |||
|
|
|
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
UTILITIES ENTRY DATA
| OPENING |
|
| |
HOLE | SIZE | USED FOR | ||
| (DIA.) |
|
| |
A | Control | Front | ||
3/4" NPS (Fem.) | Wiring | Bottom | ||
| ||||
B | Power | Front | ||
3" NPS (Fem.) | Wiring | Bottom | ||
| ||||
C | Gas Pip ing (Front)1 | |||
D | Gas Pip ing (Bot- | |||
tom)1,2 |
|
11" pip ing MPT re quired
2 Open ing in the bot tom of the unit can be lo cated by the slice in the in su la tion.
RETURN AIR
SUPPLY AIR
OUTDOOR AIR
OUTDOOR AIR (Economizer)
BLOWER |
| ECONOMIZER / MOTORIZED DAMPER, | |
| FIXED OUTDOOR INTAKE AIR AND | ||
ACCESS | |||
POWER EXHAUST RAIN HOODS | |||
BLOWER MOTOR | DISCONNECT SWITCH | ||
(See detail "Y") |
ACCESS | LOCATION |
|
| COMPRESSOR | |
BLOWER |
|
|
|
| ACCESS |
|
|
|
| (See detail "X") | |
COMPARTMENT |
|
|
|
| OPTIONAL |
ACCESS |
|
|
|
| |
(Auxiliary) |
|
|
|
| COIL GUARD |
|
|
|
|
| KIT |
DOT PLUG |
|
|
|
|
|
(For pressure |
|
|
|
| |
Drop Reading) |
|
|
|
| |
|
|
|
|
| |
GAS HEAT |
|
|
|
|
|
ACCESS |
|
|
|
|
|
VENT AIR |
|
|
|
| CONDENSER |
OUTLET |
|
|
|
| COILS |
HOODS |
| 21" |
|
|
|
|
|
|
|
| |
|
| 5" |
|
|
|
COMBUSTION |
|
|
| ||
AIR INLET |
|
|
|
| |
|
|
|
|
| |
HOOD |
|
|
|
| |
|
|
|
|
| |
|
| 92" |
|
| |
(C) |
|
|
| (A) | |
GAS SUPPLY |
|
|
| ||
|
|
|
| CONTROL WIRING | |
ENTRY |
|
|
|
| |
|
|
| ENTRY | ||
|
|
|
| ||
| CONTROL BOX | 35" |
| (B) | |
| ACCESS |
| |||
|
|
| POWER WIRING | ||
|
|
| BOTTOM SUPPLY | ||
|
|
| ENTRY | ||
FRONT |
|
| AND RETURN |
|
|
|
| AIR OPENINGS |
|
| |
(See Note) |
|
| |||
VIEW |
|
| |||
|
|
| |||
| RETURN |
|
| ||
|
| AIR |
|
| |
|
| 33" |
|
|
|
|
| SUPPLY |
|
|
|
|
| AIR |
|
|
|
|
|
|
|
| |
|
|
|
|
| |
UNIT BASE WITH RAILS |
|
|
| (B) |
|
Shown separately to illustrate | (D) |
|
|
| |
|
| POWER WIRING | |||
Bottom Duct openings, Power | GAS SUPPLY |
|
| ||
|
| ENTRY | |||
and Gas Piping Connection | ENTRY |
|
| ||
|
|
|
| ||
locations |
|
|
| (A) |
|
|
|
| CONTROL WIRING | ||
|
|
| ENTRY | ||
NOTE: |
|
|
| ||
|
|
|
| ||
For curb mounted units, refer to the curb hanger |
|
|
| ||
|
|
| |||
dimensions of the curb for the proper size of the |
|
|
| ||
|
| ||||
supply and return air duct connections. |
|
| |||
|
|
|
|
CLEARANCES
Front | 36" | |
Back | 24" (Less Econo mizer) | |
49" (With Econo mizer) | ||
| ||
Left Side (Fil ter Ac cess) | 24" (Less Econo mizer) | |
36" (With Econo mizer) | ||
| ||
Right Side (Cond. Coil) | 36" | |
Be low Unit1 | 20" | |
| 72" With 36" Maxi mum | |
Above Unit2 | Hori zon tal Over hang | |
| (For Con denser Air | |
| Dis charge) |
1U nits (ap pli ca ble in U.S.A. only) may be in stalled on com bus ti ble floors made from wood or class A, B or C roof cov er ing ma te rial.
2Units must be in stalled ou doors. Over hang ing struc tures or shrubs should not ob struct con denser air dis charge out let.
NOTE:
ELEC/ELEC Mod els: Units and duct work are ap proved for zero clear ance to RETURN AIRcombustiblematerialswhenequippedwithelectricheaters.
SUPPLY AIRGAS/ELEC Mod els: A 1" clear ance must be pro vided be tween any com bus ti ble ma te rial and the sup ply air duct work for a dis tance of 3 feet
OUTDOOR AIR
from the unit.
OUTDOOR AIRThe prod ucts of com bus tion must not be al lowed to ac cu mu late within a (Economizer)confinedspaceandrecirculate.
Lo cate unit so that the vent air out let hood is at least:
?Three (3) feet above any forced air in let lo cated within 10 hori zon tal feet (ex- clud ing those in te gral to the unit).
?Four (4) feet be low, 4 hori zon tal feet from, or 1 foot above any door or grav ity air in let into the build ing.
10 | Unitary Products Group |