PRODUCT NOMENCLATURE

262259-YTG-B-0107

PRODUCT NOMENCLATURE

15-25 Ton Sunline 2000™ Model Number Nomenclature

D M 180 N24 A 2 A AA 1 0 1 2 4 A

Product Category

D = A/C, Single Pkg., R-22

Product Identifier

M = 8.5-9.0 EER A/C

Nominal Cooling Capacity

180 = 15 Ton

240 = 20 Ton

300 = 25 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No field installed electric heat

Gas Heat Options

N24 = 240 MBH Output Aluminized Steel

N32 = 320 MBH Output Aluminized Steel

S24 = 240 MBH Output Stainless Steel

S32 = 320 MBH Output Stainless Steel

Electric Heat Options

E18 = 18 KW

E36 = 36 KW

E54 = 54 KW

E72 = 72 KW

Airflow

A = Std. Drive

B = Std. Drive/Single Input Econo.

C = Std. Drive/Single Input Econo./Power Exhaust (Downflow Only)

D = Std. Drive/Motorized Damper N = Hi Static Drive

P = Hi Static Drive/Single Input Econo.

Q = Hi Static Drive/Single Input Econo./Power Exhaust (Downflow Only)

R = Hi Static Drive/Motorized Damper

Voltage

2 = 208/230-3-60

4 = 460-3-60

5 = 575-3-60

Product Style

A = Style A

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

CPC Controller, DFS, APS

Johnson Controller, DFS, APS

Honeywell Controller, DFS, APS

Novar Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

Hot Gas Bypass (Standard on VAV, Optional on CV)

Variable Air Volume (VFD) - Not Available with Factory Installed BAS Options

Variable Air Volume (VFD With Manual Bypass) - Not Available with Factory Installed BAS Options Variable Air Volume (VFD-Ready for Customer Installed Drive)

2" Pleated filters 4" Pleated filters

BAS Ready Unit with Belimo Economizer

Double Wall Construction

Heat Reclaim Coil Options (2 or 3 Row, 1-5/8" or 2-1/8" Stub Out) (WJ and WR models only)

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

 

 

Product Generation

 

 

 

 

 

 

 

 

 

 

1 = First Generation

 

 

 

 

2 = Second Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional Options

 

 

 

 

 

 

Standard Cabinet

Hinged Filter Door & Toolless Access Cabinet

 

 

 

 

AA = None

BA = Hinged Filter Door & Toolless Access Panels

 

AB = Phase Monitor

BB = Phase Monitor, Hinged Filter Door & Toolless

 

AC = Coil Guard

Access Panels

 

AD = Dirty Filter Switch

BC = Coil Guard, Hinged Filter Door & Toolless

 

AE = Phase Monitor & Coil Guard

Access Panels

 

AF = Phase Monitor & Dirty Filter Switch

BD = Dirty Filter Switch, Hinged Filter Door &

 

AG = Coil Guard & Dirty Filter Switch

Toolless Access Panels

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

BE = Phase Monitor & Coil Guard, Hinged Filter

 

RC = Coil Guard & American Flag

Door & Toolless Access Panels

 

TA = Technicoat Condenser Coil

BF = Phase Monitor & Dirty Filter Switch, Hinged

 

TJ = Technicoat Evaporator Coil

Filter Door & Toolless Access Panels

 

TS = Technicoat Evaporator & Condenser Coils

BG = Coil Guard & Dirty Filter Switch, Hinged Filter

 

 

 

 

 

Door & Toolless Access Panels

 

 

 

 

 

BH = Phase Monitor, Coil Guard & Dirty Filter Switch,

 

 

 

 

 

Hinged Filter Door & Toolless Access Panels

 

 

 

 

ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be

 

 

located in digits 15-18.

 

 

 

 

 

 

 

 

 

 

Installation Options

 

 

 

 

 

A = No Options Installed

 

B = Option 1

 

C = Option 2

 

D = Options 1 & 2

 

E = Option 3

 

F = Option 4

 

G = Options 1 & 3

 

H = Options 1 & 4

 

J = Options 1, 2 & 3

 

K = Options 1, 2, & 4

 

L = Options 1,3 & 4

 

M = Options 1, 2, 3, & 4

 

N = Options 2 & 3

 

P = Options 2 & 4

 

Q = Options 2, 3, & 4

 

R = Options 3 & 4

 

S = Option 5

 

T = Options 1 & 5

 

U = Options 1, 3, & 5

 

V = Options 1, 4, & 5

 

W = Options 1, 3, 4, & 5

 

X = Options 3 & 5

 

Y = Options 4 & 5

 

Z = Options 3, 4 & 5

 

 

 

 

 

 

Options

 

1 = Disconnect

2= Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet