262259-YTG-B-0107

TABLE 1: SOUND POWER RATING1

 

 

ESP

BLOWER

 

 

 

 

SOUND POWER (db 10-12

Watts)

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

Octave Band Centerline Frequency (Hz)

 

SWL

dB(A)

SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@

 

 

IWG

RPM

BHP

63

125

 

250

500

1,000

2,000

 

4,000

8,000

dB(A)

 

 

 

 

10Ft.2

 

 

 

 

 

180

6,000

1.00

1,080

4.60

99

99

 

89

82

84

77

 

72

67

89

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

8,000

1.00

1,120

6.65

102

102

 

92

85

87

80

 

75

70

92

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

10,000

1.30

1160

12.5

108

108

 

98

91

93

86

 

81

76

98

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings.

2.At a distance of 10 feet from the blower.

TABLE 2: CAPACITY RATINGS - (ARI 360)1

MODEL

MBH

EER2

IPLV3

COOLING ONLY

 

 

 

DM180C/E00

176

8.7

9.2

DM240C/E00

234

8.6

8.05

DM300C/E00

272

8.5

9.2

COOLING WITH GAS HEAT

 

 

 

DM180N/S

176

8.5

9.0

DM240N/S

232

8.5

8.05

DM300N/S

272

8.5

9.0

COOLING WITH ELECTRIC HEAT

 

 

DM180E18

176

8.7

9.2

DM180E36

176

8.6

9.1

DM180E54

174

8.5

8.7

DM180E72

174

8.5

8.7

DM240E18

234

8.5

8.05

DM240E36

234

8.5

8.05

DM240E54

232

8.5

8.05

DM240E72

232

8.5

8.05

DM300E18

272

8.5

9.1

DM300E36

272

8.5

9.1

DM300E54

270

8.5

9.0

DM300E72

270

8.5

9.0

1.Certified in accordance with the Unitary Large Equip- ment certification program which is based on ARI Stan- dard 340/360.

2.EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt).

3.IPLV = Integrated Part Load Value.

TABLE 3: GAS HEAT RATIINGS

MODEL

MBH INPUT

MBH OUTPUT

DM180N/S24

300

240

 

 

 

DM180N/S32

400

320

DM240N/S24

300

240

 

 

 

DM240N/S32

400

320

DM300N/S24

300

240

 

 

 

DM300N/S32

400

320

NOTE: All gas units are two-stage heating. First stage is 50% of total.

S.S.E. = Steady State Efficiency (80%) - output divided by input.

For units with VFD and electric or gas heat, the speed of the indoor blower motor continues to be controlled by duct static pressure via the VAV control board.

If there are VAV boxes present in the duct sys- tem, the boxes must be driven to the full-open position using a customer-supplied power source to assure adequate airflow across elec- tric heating elements or gas heat exchanger tubes.

Unitary Products Group

9

Page 9
Image 9
York DM 300, DM 240, DM 180 warranty Sound Power RATING1, Capacity Ratings ARI, GAS Heat Ratiings

DM 180, DM 240, DM 300 specifications

The York DM series, including the DM 240, DM 180, and DM 300, represents a blend of efficiency, advanced technology, and reliability in the world of HVAC solutions. Designed for commercial and industrial applications, these models cater to diverse temperature control needs while maintaining energy efficiency.

The York DM 240 is engineered to provide powerful cooling and heating performance in a compact unit. It features a robust design that incorporates high-efficiency compressors and environmentally friendly refrigerants. The DM 240 boasts advanced microprocessor controls, allowing for precise temperature regulation and operational monitoring. This model is particularly known for its low noise levels, making it suitable for areas requiring a quieter environment.

The DM 180 model is similarly designed but tailored for smaller applications while still delivering exceptional energy performance. Enhanced with variable-speed fans, the DM 180 can adjust its airflow based on real-time demand, ensuring optimal comfort and reduced energy consumption. This unit also includes advanced diagnostic tools that streamline maintenance and troubleshooting, thus minimizing downtime.

The DM 300 stands out with its increased capacity and enhanced features for larger facilities. Known for its superior cooling efficiency, the DM 300 utilizes advanced inverter technology. This allows the system to vary the speed of the compressor and fans, resulting in significant energy savings and improved load matching. Additionally, the DM 300 incorporates smart connectivity features that enable remote monitoring and control via smartphone or PC, facilitating effortless management of your HVAC system.

All three models in the York DM series incorporate cutting-edge technologies, including enhanced filtration systems that improve indoor air quality by reducing airborne particles. These systems are designed to work seamlessly with modern building management systems, enabling integration and optimization of overall HVAC operations.

Durability is a noteworthy characteristic of the York DM series, as each unit is built with high-quality materials to withstand demanding environments. With easy access to components, maintenance is simplified, helping to extend the lifespan of the equipment.

In summary, the York DM 240, DM 180, and DM 300 models exemplify modern HVAC technology, combining efficiency, advanced features, and user-friendly interfaces for robust climate control solutions in any commercial or industrial setting.