York DM 180, DM 300 Factory-Installedoptions, Unit Cutaway, Gas/Electric, Unit Shown, YTG-B-0107

Models: DM 180 DM 240 DM 300

1 40
Download 40 pages 35.24 Kb
Page 5
Image 5
GAS/ELECTRIC

262259-YTG-B-0107

ELECTRIC HEATER LOCATION (OPTIONAL ELECTRIC/ELECTRIC UNITS)

 

 

HIGH EFFICIENCY COMPRESSORS

LONG LASTING

20 GAUGE ALUMINIZED STEEL

WITH CRANKCASE HEATERS

COPPER TUBE/ALUMINUM FIN

POWDER PAINT FINISH

TUBULAR HEAT EXCHANGERS

 

 

CONDENSER COILS

ECONOMIZER HOOD

2" DISPOSABLE UNIT SHOWN FILTERS

OUTDOOR AIR OPENING

FOR SLIDE-IN/PLUG-IN

INTERNAL ECONOMIZER(OPTION)

SIDE AND BOTTOM

SUPPLY & RETURN AIR

DUCT OPENINGS(SIDE X SIDE)

1" NPTI

CONDENSATE DRAINBELT-DRIVE BLOWER MOTOR

FULL PERIMETER 14 GUAGE BASE

RAILS WITH LIFTING HOLES

LOW VOLTAGE RELAY BOARD

AND TERMINAL STRIP

ELECTRICAL DISCONNECT MOUNTING LOCATION (Field installed)

KNOCKOUT FOR

SIDE CONTROL WIRING ENTRY

KNOCKOUT FOR

SIDE POWER WIRING ENTRY SIDE

TERMINAL BLOCK

(For Single Point Power Supply with Electric Heat)

ELECTRIC\ELECTRIC UNITS

BOTTOM POWER & CONTROL

WIRING ENTRY

KNOCKOUTS FOR SIDE

GAS SUPPLY ENTRY

HOLE FOR BOTTOM

 

GAS SUPPLY ENTRY

 

 

POWER VENTOR MOTOR

 

GAS/ELECTRIC

WITH POST PURGE CYCLE

 

UNIT SHOWN

LOCATION OF VFD (Optional)

 

 

 

LOCATION OF VFD Bypass (Optional)

 

FIGURE 1 - UNIT CUTAWAY

with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards.

The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit.

Electric Heat Operation - All electric heat models (fac- tory installed only) are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to pro- vide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive current and temperature by fuses and two thermal limit switches.

The power supply wiring can be routed into the control box through a threaded pipe connection in the base pan of the unit or through a knockout in the wiring panel on the front of the unit.

BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as Simplicity® INTELLI-Com- fort™, Novar, Honeywell, Johnson, and CPC.

FACTORY-INSTALLED OPTIONS

SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capa-

ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

POWER EXHAUST - Our single economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation.

The exhaust fan, motor and controls are installed and wired at the factory. The rain hood must be assembled and installed in the field.

The power exhaust option can only be used on bot- tom duct configurations.

MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in /plug-in damper assembly with a 2- position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is oper- ating and will drive fully closed when the blower unit shuts down.

The rain hood is painted to match the basic unit and must be field assembled before installing.

PHENOLIC COATED EVAPORATOR AND CON- DENSER COILS - Special coating process that utilizes Technicoat 10-1" processes. Coating is applied by total immersion of the complete coil for maximum protection.

Unitary Products Group

5

Page 5
Image 5
York DM 180, DM 300, DM 240 warranty Factory-Installedoptions, Unit Cutaway, Gas/Electric, Unit Shown, YTG-B-0107