COOLING CAPACITY - Variable Speed Air Handler
UNIT | N1VS AIR HANDLER |
| COIL MODEL1 |
|
| COOLING |
|
| |||
| ELECTRIC |
| STAGE | RATED | NET MBH |
|
| ||||
MODEL | MODEL | W | SEER | EER | |||||||
HEAT KW 2 |
| (# CYL) | CFM |
|
| ||||||
| TOTAL | SENS. | |||||||||
| N1VSB12 | 5,7.5,10,15,18 | 17 | G2FD046S17 | 1 | 630 | 15200 | 12200 | 15.5 | 13.7 | |
| 2 | 1050 | 29000 | 21400 | 12.0 | ||||||
|
|
|
|
|
| ||||||
E4TS030 |
|
|
| G2FD042S21 | 1 | 650 | 15000 | 12000 | 15.4 | 13.6 | |
N1VSC16 | 5,7.5,10,15,20 | 21 | 2 | 1065 | 28600 | 21000 | 11.9 | ||||
|
|
| |||||||||
| G2FD048S21 | 1 | 650 | 15800 | 12600 | 15.7 | 13.9 | ||||
|
|
|
| ||||||||
|
|
|
| 2 | 1065 | 30000 | 22000 | 12.1 | |||
|
|
|
|
|
| ||||||
| N1VSC16 | 5,7.5,10,15,20 | 21 | G2FD048S21 | 1 | 770 | 21400 | 15400 | 15.0 | 13.3 | |
E4TS036 | 2 | 1185 | 36000 | 25600 | 11.6 | ||||||
|
|
|
|
| |||||||
N1VSD20 | 7.5,10,15,20,25,30 | 24 | G2FD048S24 | 1 | 780 | 21600 | 15600 | 15.2 | 13.6 | ||
| |||||||||||
| 2 | 1200 | 36400 | 26000 | 11.8 | ||||||
|
|
|
|
|
| ||||||
| F(2,3)FV060 | 10,15,20,25 |
| – | 1 | 1040 | 26800 | 21800 | 15.0 | 13.6 | |
|
| 2 | 1600 | 48000 | 35600 | 11.4 | |||||
|
|
|
|
|
| ||||||
E4TS048 |
|
| 24 | G2FD060S24 | 1 | 1040 | 26800 | 21800 | 15.0 | 13.6 | |
N1VSD20 | 7.5,10,15,20,25,30 | 2 | 1605 | 48000 | 35600 | 11.4 | |||||
|
|
|
| ||||||||
|
| G2FD061H24 | 1 | 1040 | 27400 | 22200 | 15.2 | 13.8 | |||
|
|
|
| ||||||||
|
|
|
| 2 | 1605 | 49000 | 36400 | 11.6 | |||
|
|
|
|
|
| ||||||
| F(2,3)FV060 | 10,15,20,25 |
| – | 1 | 1220 | 27800 | 23400 | 14.5 | 13.2 | |
|
| 2 | 1875 | 55500 | 40500 | 10.4 | |||||
|
|
|
|
|
| ||||||
E4TS060 |
|
| 24 | G2FD060S24 | 1 | 1200 | 27800 | 23400 | 14.5 | 13.2 | |
N1VSD20 | 7.5,10,15,20,25,30 | 2 | 1860 | 55500 | 40500 | 10.4 | |||||
|
|
|
| ||||||||
|
| G2FD061H24 | 1 | 1200 | 29000 | 24000 | 14.7 | 13.4 | |||
|
|
|
| ||||||||
|
|
|
| 2 | 1860 | 57000 | 41500 | 10.6 | |||
|
|
|
|
|
|
1.G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2.Single phase units require single phase 2HK heaters.
COOLING CAPACITY - Variable Speed Furnace
UNIT | VARIABLE SPEED |
|
|
|
| COOLING |
|
| ||
W | COIL MODEL STAGE | RATED | NET MBH1 |
|
| |||||
MODEL | FURNACE MODEL | SEER2 | EER3 | |||||||
|
| (# CYL) | CFM |
|
| |||||
|
|
|
| TOTAL | SENS. |
|
| |||
| P1XDB12V | 17 | G2FD046S17 | 1 | 580 | 13800 | 10400 | 15.0 | 13.3 | |
| 2 | 1040 | 28200 | 20800 | 11.6 | |||||
|
|
|
|
| ||||||
|
|
| G2FD046S17 | 1 | 570 | 13800 | 10400 | 15.0 | 13.3 | |
|
|
| 2 | 1020 | 28000 | 20600 | 11.6 | |||
|
|
|
|
| ||||||
| P1XUB12V | 17 | G1UA048S17 | 1 | 570 | 13800 | 10400 | 15.0 | 13.3 | |
| 2 | 1020 | 28000 | 20600 | 11.6 | |||||
|
|
|
|
| ||||||
|
|
| G1FA048S17 | 1 | 570 | 13800 | 10400 | 15.0 | 13.3 | |
|
|
| 2 | 1020 | 28000 | 20600 | 11.6 | |||
|
|
|
|
| ||||||
|
|
| G2FD046S17 | 1 | 540 | 13600 | 10200 | 15.0 | 13.4 | |
|
|
| 2 | 1050 | 28200 | 20800 | 11.7 | |||
|
|
|
|
| ||||||
E4TS030 | P1DUB16V | 17 | G1UA048S17 | 1 | 540 | 13600 | 10200 | 15.0 | 13.4 | |
2 | 1050 | 28200 | 20800 | 11.7 | ||||||
|
|
|
|
| ||||||
|
|
| G1FA048S17 | 1 | 540 | 13600 | 10200 | 15.0 | 13.4 | |
|
|
| 2 | 1050 | 28200 | 20800 | 11.7 | |||
|
|
|
|
| ||||||
|
|
| G2FD042S21 | 1 | 600 | 13600 | 10400 | 14.8 | 13.2 | |
|
|
| 2 | 1100 | 28000 | 20600 | 11.4 | |||
|
|
|
|
| ||||||
|
|
| G1UA048S21 | 1 | 600 | 13800 | 10600 | 15.2 | 13.6 | |
| P1XUC16V | 21 | 2 | 1100 | 28800 | 21400 | 11.6 | |||
|
|
| ||||||||
| G1FA048S21 | 1 | 600 | 13800 | 10600 | 15.2 | 13.6 | |||
|
|
| ||||||||
|
|
| 2 | 1100 | 28800 | 21400 | 11.6 | |||
|
|
|
|
| ||||||
|
|
| G2FD048S21 | 1 | 600 | 14200 | 10800 | 15.3 | 13.7 | |
|
|
| 2 | 1100 | 29000 | 21400 | 11.8 | |||
|
|
|
|
|
For notes see Page 7.
Unitary Products Group | 5 |