036-21342-002 Rev. E (0505)

HEATING PERFORMANCE DATA

E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION

 

ID CFM

 

980

 

1065

 

1210

OD DB

 

ID DB (°F)

MBTUH1,2

 

KW

MBTUH1,2

 

KW

MBTUH1,2

 

KW

 

 

60

35.86

 

2.17

36.10

 

2.19

36.34

 

2.20

60

 

70

33.48

 

2.30

33.93

 

2.31

34.39

 

2.32

 

 

80

31.09

 

2.43

31.77

 

2.44

32.44

 

2.45

 

 

60

28.88

 

2.04

29.01

 

2.07

29.14

 

2.09

47

 

70

26.78

 

2.14

27.00

 

2.17

27.22

 

2.19

 

 

80

24.68

 

2.24

24.99

 

2.26

25.29

 

2.29

 

 

60

22.40

 

1.90

22.79

 

1.92

23.17

 

1.94

35

 

70

20.57

 

1.98

20.94

 

2.00

21.31

 

2.02

 

 

80

18.73

 

2.05

19.10

 

2.08

19.46

 

2.10

 

 

60

16.95

 

1.71

17.09

 

1.74

17.22

 

1.78

17

 

70

15.20

 

1.77

15.40

 

1.84

15.60

 

1.83

 

 

80

13.46

 

1.83

13.71

 

1.94

13.97

 

1.88

 

 

60

12.23

 

1.50

12.34

 

1.52

12.45

 

1.54

7

 

70

11.24

 

1.57

11.39

 

1.60

11.53

 

1.61

 

 

80

10.24

 

1.64

10.43

 

1.68

10.62

 

1.68

 

 

60

7.92

 

1.37

7.99

 

1.39

8.06

 

1.41

-3

 

70

7.28

 

1.43

7.37

 

1.46

7.47

 

1.47

 

 

80

6.63

 

1.49

6.75

 

1.53

6.87

 

1.53

E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION

 

ID CFM

 

650

 

720

 

770

OD DB

 

ID DB (°F)

MBTUH1,2

 

KW

MBTUH1,2

 

KW

MBTUH1,2

 

KW

 

 

60

20.36

 

1.08

20.52

 

1.09

20.67

 

1.09

60

 

70

18.50

 

1.16

18.66

 

1.17

18.81

 

1.17

 

 

80

16.64

 

1.24

16.79

 

1.25

16.95

 

1.25

 

 

60

16.02

 

1.05

16.15

 

1.06

16.28

 

1.08

47

 

70

14.90

 

1.12

15.00

 

1.13

15.10

 

1.14

 

 

80

13.77

 

1.19

13.85

 

1.20

13.93

 

1.20

 

 

60

12.60

 

1.02

12.71

 

1.04

12.82

 

1.07

35

 

70

12.00

 

1.08

12.07

 

1.10

12.13

 

1.12

 

 

80

11.40

 

1.13

11.42

 

1.15

11.45

 

1.16

For notes see Page 11.

Multipliers for determining the performance with other indoor sections.

2-CYLINDER OPERATION

Air Handler

Coil

HIGH CFM

LOW CFM

 

 

 

 

MBTUH

KW

MBTUH

KW

 

 

 

 

 

 

 

 

N1VSB12

G2FD046S17

0.98

0.99

0.91

0.96

 

 

 

 

 

 

N1VSC16

G2FD042S21

0.96

0.98

0.90

0.95

 

 

 

 

 

 

 

 

 

 

 

 

Variable Speed

Coil

MBTUH

KW

MBTUH

KW

Furnace

 

 

 

 

 

P1XDB12V

G2FD046S17

0.97

1.00

0.89

0.94

 

 

 

 

 

 

P1XUB12V

G2FD046S17

0.96

1.00

0.88

0.95

 

 

 

 

 

 

P1XUB12V

G1UA048S17

0.96

1.00

0.88

0.95

 

 

 

 

 

 

P1XUB12V

G1FA048S17

0.96

1.00

0.88

0.95

 

 

 

 

 

 

P1DUB16V

G2FD046S17

0.98

1.00

0.90

0.95

 

 

 

 

 

 

P1DUB16V

G1UA048S17

0.98

1.00

0.90

0.95

 

 

 

 

 

 

P1DUB16V

G1FA048S17

0.98

1.00

0.90

0.95

 

 

 

 

 

 

P1DUC16V

G2FD042S21

1.00

1.00

0.92

0.95

 

 

 

 

 

 

P1DUC16V

G1UA048S21

1.01

1.01

0.93

0.96

 

 

 

 

 

 

P1DUC16V

GFA048S21

1.01

1.01

0.93

0.96

 

 

 

 

 

 

P1DUC16V

G2FD048S21

1.02

1.02

0.94

0.97

 

 

 

 

 

 

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

1-CYLINDER OPERATION

Air Handler

Coil

LOW CFM

 

 

MBTUH

KW

 

 

 

 

 

 

N1VSB12

G2FD046S17

0.89

0.91

 

 

 

 

N1VSC16

G2FD042S21

0.88

0.90

 

 

 

 

 

 

 

 

Variable Speed

Coil

MBTUH

KW

Furnace

 

 

 

P1XDB12V

G2FD046S17

0.85

0.93

 

 

 

 

P1XUB12V

G2FD046S17

0.85

0.93

 

 

 

 

P1XUB12V

G1UA048S17

0.85

0.93

 

 

 

 

P1XUB12V

G1FA048S17

0.85

0.93

 

 

 

 

P1DUB16V

G2FD046S17

0.83

0.91

 

 

 

 

P1DUB16V

G1UA048S17

0.83

0.91

 

 

 

 

P1DUB16V

G1FA048S17

0.83

0.91

 

 

 

 

P1DUC16V

G2FD042S21

0.87

0.91

 

 

 

 

P1DUC16V

G1UA048S21

0.88

0.92

 

 

 

 

P1DUC16V

GFA048S21

0.88

0.92

 

 

 

 

P1DUC16V

G2FD048S21

0.89

0.92

 

 

 

 

18

Unitary Products Group

Page 18
Image 18
York E4TS030 THRU 060 warranty Heating Performance Data, Cylinder Operation, High CFM LOW CFM Mbtuh, Variable Speed Coil

E4TS030 THRU 060 specifications

The York E4TS030 through E4TS060 are a series of air-cooled chillers designed for commercial and industrial applications. These chillers are renowned for their high efficiency, reliability, and advanced technology, making them a popular choice among HVAC professionals and building managers.

One of the main features of the E4TS series is its energy efficiency. With a variable-speed scroll compressor, the E4TS chillers can adjust their capacity according to the cooling demand, which significantly reduces energy consumption. This technology not only contributes to lower operational costs but also aids in minimizing the environmental impact. The units are designed to achieve high energy efficiency ratios (EER) and seasonal energy efficiency ratios (SEER), making them suitable for energy-conscious applications where reducing carbon footprint is a priority.

Another significant characteristic of the E4TS030 to E4TS060 models is their compact design. These chillers are engineered to occupy less space, making them ideal for installations where space is at a premium. The units are constructed with durable materials that withstand various environmental conditions, ensuring longevity and reliability. Additionally, the modular design allows for easy installation and maintenance, providing flexibility for retrofit projects or new constructions.

In terms of control technology, the E4TS series is equipped with advanced microprocessor controls that facilitate precise temperature management and system diagnostics. The intuitive interface allows operators to monitor the system’s performance in real-time, optimizing efficiency and helping to prevent potential issues before they escalate.

Noise reduction is another important feature of the E4TS chillers. These units incorporate sound-dampening technologies and design elements that minimize operational noise, making them suitable for use in noise-sensitive applications, such as schools, hospitals, and office buildings.

Furthermore, the York E4TS series supports various refrigerant options, including environmentally friendly refrigerants, aligning with global initiatives to reduce greenhouse gas emissions. This flexibility enables users to select a refrigerant that meets their specific environmental goals and regulatory requirements.

In summary, the York E4TS030 THRU 060 chillers present a winning combination of energy efficiency, compact design, advanced controls, and low noise operation. Their robust construction and commitment to sustainability make them an excellent choice for a wide range of commercial cooling applications, ensuring optimal performance and reliability over their lifespan.