ERROR CODES FOR THE POWER WAVE®
The following is a partial list of possible error codes for the POWER WAVE® i400. For a complete listing consult the Service Manual for this machine.
POWER SOURCE–––WELD CONTROLLER
| Error Code # | LECO | Indication |
|
| (FANUC#) |
|
31 | Primary (Input) overcurrent error. | 49 | Excessive Primary current present. May be related to a |
|
|
| switch board or output rectifier failure. |
32 | Capacitor “A” under voltage | 50 | Low voltage on the main capacitors. May be caused by |
| (right side facing the Switch PC Board) |
| improper input configuration, or an open/short circuit in the |
33 | Capacitor bank "B" under voltage | 51 | primary side of the machine. |
| (left side facing the Switch PC Board) |
| |
|
|
| |
34 | Capacitor "A" over voltage | 52 | Excess voltage on the main capacitors. May be caused by |
| (right side facing the Switch PC Board) | improper input configuration, excessive line voltage, or | |
|
| ||
35 | Capacitor "B" over voltage | 53 | improper capacitor balance (see Error 43) |
| (left side facing the Switch PC Board) |
| |
36 | Thermal error | 54 | Indicates over temperature. Usually accompanied by |
|
| Thermal LED. Check fan operation. Be sure process does | |
|
|
| not exceed duty cycle limit of the machine. |
37 | Softstart | 55 | Capacitor precharge failed. Usually accompanied by |
|
|
| codes 32 and 33. |
39 | Misc. hardware fault | 57 | Unknown glitch has occurred on the fault interrupt circuit- |
|
|
| ry. Sometimes caused by primary over current fault, or |
|
|
| intermittent connections in the thermostat circuit. |
43 | Capacitor delta error | 67 | The maximum voltage difference between the main capac- |
|
|
| itors has been exceeded. May be accompanied by errors |
|
|
| |
|
|
| or secondary circuit(s). |
54 | Secondary (output) over current | 84 | The long term average secondary (weld) current limit has |
|
|
| been exceeded. This error will immediately turn off the |
|
|
| machine output. |
|
|
| NOTE: The long term average secondary current limit is |
|
|
| 450 amps. |
|
|
|
|
|
|
| A complete list of error codes is available in the |
|
|
| Diagnostics Utility (included on the POWER WAVE® |
|
| see com- | Utilities and Service Navigator CDʼs or available at |
Other |
| www.powerwavesoftware.com). | |
| plete |
| |
|
| listing | Error codes that contain three or four digits are defined as |
|
|
| fatal errors. These codes generally indicate internal errors |
|
|
| on the Power Source Control Board. If cycling the input |
|
|
| power on the machine does not clear the error, contact the |
|
|
| Service Department |