A-6

 

INSTALLATION

A-6

 

 

 

OPTIONAL EQUIPMENT

 

 

System

Part No.

Description

 

 

Identifier

 

 

 

 

 

K1796-xx

Coax Cable. Recommended to minimize the effects of the weld cable loop inductance and maximize perfor-

 

 

mance in critical high speed pulse applications.

 

 

Coaxial Weld Cable

K2593-xx

Note: K1796 coaxial cable is equivalent to 1/0 standard cable. K2539 coaxial cable is equivalent to AWG #1

 

 

standard cable. Connecting coaxial cables in parallel to increase current carrying capacity can significantly

 

 

 

reduce their inductance minimizing properties, and is therefore NOT RECOMMENDED. Consult the Output

 

 

 

Cable Guidelines for further information.

 

 

External Dress

K2709-xx

External Dress Cable. Heavy duty externally mounted 14pin wire feeder cable for use with robot arms not

 

Cable for Robot

 

 

equipped with an integral cable.

 

 

Arm

 

 

 

 

 

 

 

Personal Computer

Customer

IBM Compatible PC (Windows NT SP6, Windows 2000, Windows XP, or greater) required for use with all

 

Supplied

POWER WAVE® Utilities

 

 

 

 

 

Replacement

K2673-2

POWER WAVE® i400 Replacement Chassis. Complete inverter power section. Intended only as a replace-

 

Chassis

 

ment to be installed in the POWER WAVE® i400 cabinet (includes S26064 POWER WAVE® Utilities CD).

 

 

 

 

 

POWER WAVE i400

Page 15
Image 15
Lincoln Electric IM986 manual Power Wave Utilities