TROUBLESHOOTING

E-11

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Output will not come on.

6. Other modules faulted.

6.

Verify no other modules are faulted

 

 

 

 

(all system Status Lights should be

 

 

 

 

steady green). Use Diagnostics Utility

 

 

 

 

to display any current faults in the sys-

 

 

 

 

tem.

Bad Weld Starting.

1. Wire Feed problem

1.

Verify Feeders drive roll tension is not

 

 

 

 

too low allowing the wire to slip in the

 

 

 

 

rolls. Verify wire can be pulled easily

 

 

 

 

through the wire conduit. Verify

 

 

 

 

Contact tip is not blocked.

 

 

 

 

 

 

2.

Strike Wire Feed Speed

2.

Verify the Strike Wire Feed Speed set

 

 

 

 

correctly.

 

 

 

 

 

 

3.

Incorrect Weld Schedule

3.

Verify the correct weld schedule is

 

 

 

 

selected.

 

 

 

 

 

 

4.

Voltage Sense Leads

4.

Verify voltage sense leads are proper-

 

 

 

 

ly connected and configured as

 

 

 

 

described in the instruction manual.

 

 

 

 

 

 

5.

Analog Scans Between Updates

5.

The DeviceNet tab of the Diagnostics

 

 

 

 

Utility displays the POWER WAVE®ʼs

 

 

 

 

“Analog Scans Between Updates” and

 

 

 

 

“I/O Scans/Sec.” Verify that “Analog

 

 

 

 

Scans Between Updates” is ¼ of “I/O

 

 

 

 

Scans/Sec” value.

 

 

 

 

 

 

6.

Analog Hysteresis

6.

From the DeviceNet tab of the

 

 

 

 

Diagnostics Utility, select Configure.

 

 

 

 

Verify in “Analog Input Channels” that

 

 

 

 

the Hysteresis settings are all 0.

 

 

 

 

 

 

7.

Limit Error

7.

Verify all analog input values are with-

 

 

 

 

in limits.

 

 

 

 

 

8.

Fan Out

8. From the DeviceNet tab of the

 

 

 

 

Diagnostics Utility, select Monitor.

 

 

 

 

Verify under “Analog Input Fan Out”

 

 

 

 

that Burnback is present for all

 

 

 

 

analogs in.

 

 

 

 

 

 

9.

Gas

9.

Verify Gas is being turned on before

 

 

 

 

the output.

 

 

 

 

 

 

 

 

 

 

Manual backgroundManual background CAUTION